SICK LCU-P Manual De Instrucciones página 354

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 127
Chapter 10
Code Fault Message
3 6
CONFIG. FAU LT: 36
PRESS ESCAPE KEY
3 7
CONFIG. FAU LT: 37
PRESS ESCAPE KEY
38
CONFIG. FAULT: 38
PRESS ESCAPE KEY
40
CONFIG. FAULT: 40
PRESS ESCAPE KEY
5 3
CHECK AUX B INPUTS
5 4
CHECK MUTING INPUTS
5 5
CHECK RMON INPUT
OUTPUT DISABLED
56
CH ECK SYS. TST I NPUT
OUTPUT DISABLED
57
CHECK CYCLE CONTACT
OUTPUT DISABLED
58
NO USER DEF. MODE 1
PRESS ESCAPE KEY
59
NO USER DEF. MODE 2
PRESS ESCAPE KEY
60
NO USER DEF. MODE 3
PRESS ESCAPE KEY
61
CONNECT RECEIVER 1
PRESS ESCAPE KEY
62
CONNECT RECEIVER 2
PRESS ESCAPE KEY
63
PSDI TI M EOUT
PRESS ESCAPE KEY
64
LOCKOUT: 64
ESPD FAI LU RE
65
LOCKOUT: 65
CH ECK ESPD COM MS
66
LOCKOUT: 66
CH ECK MPCE I NPUT
67
LOCKOUT: 67
MODE SELECT WI RI NG
68
LOCKOUT: 68
CHECK INT/EXT WIRING
354
Diagnostic Messages
Fault Description
PSDI is not allowed with TYPE 2 primary AOPDs.
Muting inputs are selected, but no receivers are
programmed as muted.
The operator has attempted to execute a mode that
requires communicatio with the primary AOPD and current-
ly, the LCU-P has no communications with the primary.
Single stroke Restart is selected, but the restart type
is not internal.
LCU-P control is operating in a Single Stroke operation
and the LCU-P control will not restart until both B inputs
have gone through their proper sequence of transitions.
Muting inputs are active when the LCU-P control is
preparing to go GREEN.
MPCE is not in the proper state for the LCU-P to
go green.
SRCS is not in the proper state for the LCU- P to
go green.
MCC is not in the proper state for the LCU-P to
go green.
The requested user defined mode 1 data is undefined.
The requested user defined mode 2 data is undefined.
The requested user defined mode 3 data is undefined.
Primary AOPD is not energised.
Secondary AOPD is not energised.
PSDI timeout has occurred.
The AOPD has indicated a lockout through comms fault.
Lost comms with AOPD during a blanking.
M PCE did not change state after LCU-P OSSds
energised.
Mode select switch has been wired improperly.
Internal and External restart select inputs are the same.
8 008 364/NB 86/25-04-00 © SICK AG • Safety Systems • Germany • All rights reserved
Operating instructions
LCU-P
Tabla de contenido
loading

Tabla de contenido