Antenna Connection; Function Modes - Cardin Elettronica PRG813 Manual Del Usuario

Programador electronico para el control de las puertas motorizadas
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

REMOTE CONTROL (fig. 1)
The system can be remotely activated using radio control devices. Two
functions are available:
- sequential command Open-Block-Close-Block;
- blocking command
The commands can be activated from any of the available channels.
SERIES S449 RADIO CONTROLS 433 MHZ
Memory module M1
This is extractable, furnished with a non volatile EEPROM type memory and
contains the transmitter codes and allows you to memorise up to 300 codes
(300 channel buttons).
The programmed codes are maintained in this module even during black-
outs.
• If the electronic card has to be replaced due to failure, the module can be
extracted from it and inserted into the new card. Make sure that the module
is correctly inserted as shown in fig. 1.
Signal LED "L2" (fig.1):
Flashing quickly:
cancels a single code
Flashing slowly:
memorises a single code
Permanently lit:
memory full.
TRANSMITTER CODE MANAGEMENT
Attention! Before memorising the transmitters for the first time
remember to cancel the entire memory content.
A) Memorising a channel (fig.1):
1. Press and hold down button "P1" MEMO: The LED "L2" will flash slowly.
2. At the same time activate the transmitter which is to be memorised.
3. Hold down button "P1" MEMO until LED "L2" starts to flash again.
4. Release the MEMO button: The LED will continue to flash.
5. Activate the transmitter again (same transmitter, same channel; if the channel
is different or it is a different transmitter the memorisation attempt will abort
without success).
6. End of memorisation: the LED "L2" will remain lit for 2 seconds, indicating
that the transmitter has been correctly memorised.
Note:
• It is not possible to memorise a code which is already in memory: if you
attempt this, the LED will switch off when you activate the transmitter (point
2).
Only after releasing the button "P1" MEMO will you be able to continue the
memorising procedure.
• If after activating the transmitter for the first time you wait for more than fifteen
seconds without activating the transmitter a second time the memorisation
attempt will abort without success.
B) Cancelling a channel (fig.1):
1. Press and hold down the button "P2" DEL: the LED "L2" will flash
quickly.
2. Activate the transmitter channel which is to be cancelled.
3. The LED will remain lit for 2 seconds, indicating that the transmitter has
been cancelled.
Note:
• If the user that you wish to cancel is not in memory, the LED will stop flash-
ing; only after releasing the button "P2" will you be able to continue the
cancellation procedure.
• For both the memorisation and cancellation procedures, if the button is
released before activating the transmitter the procedure will abort.
C) Cancelling all user codes from memory (fig.1)
1. Keep both buttons pressed down ("P1+P2") for more than four seconds.
2. LED "L2" will remain lit during the entire cancellation time (about 8 sec-
onds).
3. LED "L2" switches off when the cancellation procedure has terminated.
Note:
• When the memory is almost full the time required to search for a user code
could take up to 1 second from when the command was received.
• If led "L2" remains lit memory is completely full. To memorise a new trans-
mitter you will first have to cancel a code from memory.
D) Memorising ulterior channels via radio
• Memorisation can be activated by radio (without opening the receiver
container) if jumper "J2" has been inserted (fig. 1).
1) Make sure that the jumper "J2" has been inserted (fig. 1).
2) Using a transmitter, in which at least one
channel button "A, B, C or D" has already
been memorised in the receiver, press
the button in the transmitter as shown in
figure.
Note: all the receivers within range when the channel button is pressed (and
which have at least one of the transmitter channel buttons memorised) will
activate their signal buzzer "B1" (pag. 1).
3) Press one of the channel buttons on the same transmitter.
The receivers which do not contain that channel code will sound a five-
second long "beep" and will then deactivate.
The receivers which contain the channel code will sound a one-second long
"beep" and will enter the "programming via radio" mode.
4) Press the previously chosen channel buttons on the transmitter which you
wish to memorise; the receiver will sound 2 "beeps" of half a second each
after which the receiver will be ready to receive another code.
5) To leave the programming mode wait for 3 seconds without pressing any
buttons.
The receiver will sound a five-second long "beep" and will then exit the
programming mode.
• When the memory is entirely occupied the buzzer will sound 10 rapid "beeps"
and will automatically leave the "programming via radio" mode. Led "L2"
will remain lit on the receiver.
- The same signal is given each time you try to enter "programming via
radio" when the memory is full.

ANTENNA CONNECTION

The receiver is supplied with its own antenna which consists of a piece of rigid
wire 170 mm in length.
In alternative it is possible to connect an ANS400 tuned antenna using a coaxial
cable RG58 (impedance 50Ω) with a maximum length of 15 m.

FUNCTION MODES

Functions selected using the Dip-switch "DS1"
Pos. A (Dip 1 "ON" + Dip 2 "ON")
Automatic reclosing activated + gate delay
activated
Pos. B (Dip 1 "OFF" + Dip 2 "OFF")
Automatic reclosing excluded + gate delay
excluded
Pos. C (Dip 1 "ON" + Dip 2 "OFF")
Automatic reclosing activated + gate delay
excluded
Pos. D (Dip 1 "OFF" + Dip 2 "ON")
Automatic reclosing excluded + gate delay
activated
1) Automatic
Selected by moving dip 1 to the "ON" position.
When the door is completely closed the opening command will start a complete
cycle consisting of opening and automatic reclosing.
Automatic reclosing starts after the programmed pause period has elapsed when
the opening cycle has been completed or straight away after the intervention
of a photoelectric cell during the pause time (the intervention of a photoelectric
cell causes the pause time to be reset).
2) Semi-automatic
Selected by moving dip 1 to the "OFF" position.
Work cycle control using separate opening and closing commands.
When the door has reached the completely open position the system will wait,
until it receives a closing command either via an external control button or via
radio control, before completing the cycle.
8
MEMORIZZAZIONE CODICE TX-RX
Drawing number :
Description :
DM0531
Product Code :
RCQ449100
Draft :
P.J.Heath
Date :
13-04-2001
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/4