Installer Settings - Lamborghini Caloreclima thin 24 MCS W TOP U Manual Para La Instalación Y El Mantenimiento

Tabla de contenido

INSTALLER SETTINGS

The tasks in this section must only be carried out by qualified personnel.
Carrying out these procedures wrongly may damage the control unit and boiler or cause them to malfunction.
G CONNECTING UP TO THE OUTDOOR TEMPERATURE SENSOR.
The control unit can also be fitted with a sensor that monitors outdoor temperature.
The outdoor temperature reading utilised by the control unit may be supplied in one of two different ways:
-
when the outdoor temperature sensor is connected to the boiler the temperature reading is sent from
the boiler to the control unit.
-
when the outdoor temperature sensor is connected directly to the control unit the reading is acquired
and processed by the control unit directly.
If both are present the local sensor is ignored and the outdoor sensor connected to the boiler base is
utilised.
This situation is highlighted by the appearance of error message E67.
To connect the outdoor sensor to the control unit use the S.EXT connection on the terminal block.
With the outdoor sensor connected, pressing the
water temperature.
G ENABLING REMOTE OPERATION
The control unit has an input (TEL + and -) which allows connection of an optional control unit for distance
operation.
Operating mode:
-
TEL input open
The control unit operates as described in the handbook.
-
TEL input closed
The control unit switches to remote mode, that is:
heating and hot water functions enabled, automatic temperature regulation according to timer programme
with on-display information while upper display shows the TEL message in place of room temperature.
This mode persists until the user disables it by acting on the remote mode switch (TEL input open). Standard
operating mode is then restored.
G CLOCK SPEED CORRECTION
Allows you to improve clock precision by increasing speed (should it run slow) or decreasing speed
(should it run fast).
The entire correction procedure must be done with the control unit powered and connected to the boiler.
Clock correction:
Press key R and keep it pressed.
Press the H/Day key
Release the R key and wait for the display to show the "Hour" confirmation message.
The next two stages must be done within 5 seconds otherwise the procedure will be aborted (a change of
one unit alters clock speed by 30 seconds a year).
Release the H/day key.
Press the + key to increase clock speed (an increase of one unit speeds up the clock by 30 seconds a year).
Press the – key to reduce clock speed (a decrease of one unit slows down the clock by 30 seconds a year).
Wait 5 seconds after the last modification to exit this function and recommence normal operation.
key shows the outdoor temperature and heating
25