Hoses And Connections; Hydraulic Oil; Pressure Adjustment - Chicago Pneumatic RX 2 Instrucciones De Operación Y Seguridad

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
RX 2, 3, 4, 6, 8

Hoses and connections

WARNING
Whipping hydraulic hose
Hydraulic hoses under pressure can whip
uncontrollably if screws loosen or are loosened. A
whipping hydraulic hose can cause severe injuries.
Depressurize the hydraulic system before
loosening the connection of a hydraulic hose.
Tighten the nuts on the connections of the
hydraulic hoses to the required torque.
Type of nipple: Chicago Pneumatic JIC standard
nipple. The nipple dimensions can be found in the
Spare parts list.
The quality of the hydraulic hoses should be 2SC
(according to EN 857) or better when connecting
the breaker to the carrier. If quick couplings are to
be used, we recommend using the "Flat Face" quick
coupling. This type is sturdy and easy to clean. The
quick couplings pressure class must agree with the
carrier's working pressure.
Always clean the quick couplings before mounting
or dismounting. Always plug hoses and hose nipples
with tight and clean plugs when dismounting.
Hose connections
Right side (As seen from operator's seat)
Central lubrication
Symbol
RX 2
G ¼"
RX 3
G ¼"
RX 4
G ¼"
RX 6
G ¼"
RX 8
G ¼"
Hose connections
Left side (As seen from operator's seat)
Symbol
RX 2
RX 3
RX 4
RX 6
RX 8
9800 1050 90 | Original instructions
Tank, return line
M22 x 1.5
M26 x 1.5
M26 x 1.5
M26 x 1.5
M26 x 1.5
Pressure to
Pressure for
©
breaker
ContiLube
II
M22
-
M26
-
M26
M14 x 1.5
M26
M14 x 1.5
M26
M14 x 1.5
Safety and operating instructions
Tightening torque for pressure and return hose
RX 2
RX 3
RX 4
RX 6
RX 8

Hydraulic oil

Normally the type of hydraulic oil the carrier is using
also works for the hydraulic breaker. When a
hydraulic breaker is connected to the carrier, the
hydraulic oil will get contaminated faster. Check and
follow the carrier's instructions for changing oil and
oil filter.
It is common to change the oil filter more frequently
when a hydraulic breaker is installed.
NOTICE
When the machine is delivered it contains
some mineral based hydraulic oil. Before connecting
to the carrier's hydraulic system, check which type
of hydraulic oil the carrier is using. Mixing different
types of hydraulic oil may destroy the lubrication
quality which can lead to machine damage.
In order to protect the environment we recommend
the use of biologically degradable hydraulic oil.
Viscosity
Viscosity (permitted)

Pressure adjustment

To ensure that the accumulator and hammer are not
overloaded, a separate pressure relief valve should
be installed, see picture below. It is set at a value of
30 bar over the hammer s maximum operating
pressure. If the carrier s breaker circuit is already
equipped with a pressure limiting valve, no extra
valve is necessary.
150 Nm
150 Nm
150 Nm
150 Nm
210 Nm
15-100 cSt
13
Tabla de contenido
loading

Este manual también es adecuado para:

Rx 3Rx 4Rx 6Rx 8

Tabla de contenido