Safety equipment
Safety valve
The spring-loaded safety valve [3] triggers if the
permissible maximum pressure is exceeded.
Start-up
Assembly
Fit the wheels as shown (Fig. II).
Fit the compressed air connection [6] as
shown (Fig. III).
Check the condensate drain (Fig. I)
Ensure that the condensate drain [7] is closed.
Check the oil level (Fig. I)
Check the compressor oil level at the oil sight
glass [10].
If necessary, top up oil to the middle of the oil
sight glass (see technical data for the oil grade):
— Screw out the oil sealing screw plug [11].
— If necessary, top up oil to the middle of the oil
sight glass or the marking.
— Screw the oil sealing screw plug back in.
Fill with pneumatic oil (Fig. IV)
Screw on the compressed air oiler [19].
Fill with pneumatic oil until the oil level is between
the two markings.
Screw the compressed air oiler closed again.
Setting up
Incorrect setting up can result in severe
accidents!
Secure the device against rolling
¾
away, toppling over and slipping.
Safety devices and control elements
¾
must be easily accessible at all times.
Do not lay the device on the side. Oil
¾
may escape!
The place of installation of the device must fulfil the
following requirements:
• Dry, protected against frost
• Firm, horizontal and level ground
22
WARNING!
Transport
Do not lay the device on the side. Oil may
escape!
Do not pull the device by the hose or mains
cable. Transport the device by the transport
handle [4].
Operation

Mains supply

Electrical voltage
Only use the device in a dry envi-
¾
ronment.
Only operate the device from a
¾
power source that fulfils the following
requirements: Sockets installed ac-
cording to regulations, earthed and
checked, fuse rating according to the
technical data.
Route the mains cable so that it is not
¾
in the way during work and cannot
be damaged.
Check the device is switched off
¾
before plugging the mains plug into
the socket.
Protect the mains cable against heat,
¾
corrosive liquids and sharp edges.
Use an extension lead that has an
¾
adequate cross-section (see technical
data).
Use an extension cable approved for
¾
outside use. Outdoors, use only ap-
proved and correspondingly labelled
extension cable.
Do not switch the compressor off by
¾
pulling out the mains plug, rather
switch off at the On/Off switch.
Always connect an RCD with a
¾
maximum tripping current of 30 mA
upstream.
DANGER!