Control knobs on the gas burners
The knobs for the gas burners of the cooker are found on the control panel. The
regulating knobs should be turned in anti-clockwise direction until the small flame
symbol, vice versa for the larger flame symbol.
Ignition of the hob gas burners
To light up the burner, keep pushing the ignition button as indicated by
knob and turn it anti-clockwise to maximum, and hold it for 3 to 5 seconds.
• The ignition will spark and ignite the burner. At this position the gas supply is at the maximum
and the flame also at its maximum.
• You can reduce the flame size by turning the knob in anti-clockwise direction to achieve your
requirements.
• Should the burner fail to light up, turn the knob to its original position and try again.
• Your burner flame should be blue in color.
NOTE -When first used, the gas burner will not ignite immediately.
Time is required for the LPG to fully fill the operating system.
For 90cm ovens with bottle compartment, this same symptom will also be present when
the gas cylinder has emptied and a new cylinder installed.
Air adjustment of the burner body
The mixing ratio of LPG and air is important to provide complete combustion of gas and to
obtain a blue flame. The adjustment and nozzle used for each individual burner body on your
cooker has been designed so as to achieve this requirement.
IMPORTANT SAFETY:
In the event the flame in the oven extinguishes by itself, please take the following steps
below:
1) SHUT OFF THE OVEN CONTROL KNOBON GAS OVEN MODEL ALSO SHUT OFF
THEGASCYLINDER VALVE.
2) DO NOT RE-IGNITE THE OVEN IMMEDIATELY.
3) OPEN THE OVEN DOOR TO LET OUT UNBURNT GAS FOR AT LEAST 15 MINUTES.
4) AFTER COMPLETING STEPS 1 TO 3, RE-IGNITE THE OVEN BURNER CAREFULLY
WITH A SPARK GUN.
-45-
. Then push in the