"Lead": set ECG lead.
²
"1mV": the activation status of the internal 1mV calibration signal. Select "On" means activation of the
²
internal 1mV calibration signal, select "Off" means deactivate it. "On" means the ECG signal source will be
the internally generated 1mV signal for calibration, and the calibration signal waveform (1mV, 1Hz square
wave) will be displayed on the screen.
?
The 1mV calibration signal is used to test the ECG function of the device. It is not used during normal
operation.
"Cable": choose the number of lead wires for ECG cable to be used. "3" and "5" for optional. Only lead I, II
²
and III can be selected if "3" lead wires is set. All ECG leads including lead I, II, III, aVR, aVL, aVF, V (V1~V6)
can be selected if "5" leads wires is set. The factory default is "3".
"Notch": to choose the filter notch. 3 options: OFF, 50Hz, 60Hz. The factory default is 50Hz.
²
"Pacer": Enable the cardiac pacemaker pulse detection, the factory default is "Off". When the "Pacer" is
²
selected (set as "On"), the function of pacemaker pulse detection will be effective. A mark " " will be
overlapped on the ECG waveform. if the pacemaker pulse is detected while the patient wears a cardiac
pacemaker.
Note: pacemaker pulse inhibition function is always effective for Heart Rate calculation whether you enable or
disable the function of cardiac pacemaker pulse detection or not.
Operation Instructions:
u Key operation:
1. Press "
" key or "
turn to blue, short pressing OK "
2. Short pressing "
"
"key again to confirm and save the setting. Note: long pressing can adjust the parameter swiftly.
3. Short pressing "
u Touchscreen operation:
1. Press the parameter you want to adjust, then the screen shows the parameter value list.
2. Press "
" button and "
the setting.
3. Pressing "
" button to return to upper level screen.
Note: operation for each parameter setting is similar to ECG setup, so we will not cover it again.
User Manual for Vital Signs Monitor
" key to move cursor to select parameter. The parameter that the cursor stays will
" key, then the screen shows the parameter value list.
" key or "
" again to adjust or modify parameter value, and short pressing OK
" key to return to upper level screen.
" button to view the parameter value by page, and short tab the value to confirm