Siemens XRS-5 Guia De Inicio Rapido página 5

Ocultar thumbs Ver también para XRS-5:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Instructions specific to hazardous area installations
(Reference European ATEX Directive 94/9/EC,
The following instructions apply to equipment covered by certificate number
SIRA 99ATEX5091X.
1.
The equipment may be used with flammable gases and vapors with the Apparatus Group
II and with Temperature class T1 to T6.
2.
The equipment has a temperature class of T85 °C and may be used with flammable dusts.
3.
The equipment is certified for use in an ambient temperature range of -20 °C to +65 °C
4.
The equipment has not been assessed as a safety related device as referred to by EC
Directive 94/9/EC Annex II, clause 1.5.
5.
The certificate has a 'X' suffix, which indicates that special conditions of installation and
use apply. Those installing or inspecting this equipment must have access to the contents
of the certificate.
6.
The apparatus shall only be supplied from a circuit containing a suitably rated fuse having
a breaking capacity of at least 1500A.
7.
Installation and inspection of this equipment shall be carried out by suitably trained
personnel in accordance to the applicable code of practice (EN 60079-14 and EN 60079-17
within Europe).
8.
The equipment is non-repairable.
9.
The certification of this equipment relies upon the following materials used in its
construction:
Norton Performance Plastics Chemgrip bonding compound
ETFE housing material
PVDF housing material
Dow-Corning 3-4207 encapsulant
Royal EPOCAP 42174/52174
Cotronics Durapot 864 encapsulant
10. If the equipment is likely to come into contact with aggressive substances, then it is the
responsibility of the user to take suitable precautions that prevent it from being adversely
affected, thus ensuring that the type of protection is not compromised.
Aggressive substances: for example, acidic liquids or gases that may attack
metals, or solvents that may affect polymeric materials.
Suitable precautions: for example, establishing from the material's data sheet
that it is resistant to specific chemicals.
XRS-5
XRS-5 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567
Ambient Temp.: – 20°C to 65°C
V in: 1.77 V r.m.s.; 250 V p
I
in : 44.2 mA r.m.s.
Siemens Milltronics Process Instruments, Peterborough
Note:
Product configuration number shown for example only.
Serial number shown for example only.
A5E32299685
XRS-5 Series Transducers – QUICK START MANUAL
Annex II, 1/0/6)
Class I, Zone 1
AEx m IIC, T6, IP68
Class II, III, Div 1, Group E, F, G
Per Dwg.: 0-8650003Z-DI-A
Max. Torque: 12 FT–LBS
Class I, Div 2, Group A, B, C, D
Class II, Div 1, Group E, F, G
IP66 / IP68 (2M)
159134
II 2 G D
Ex mb IIC T6 Gb
0518
Ex tb IIIC T85°C Db
SIRA 99ATEX5091X
IECEx SIR 09.0005X
WARNING:
Static Hazard,
Do Not Rub With Dry Cloth.
.
KCC-REM-S49
Echomax
OCP 0017
Ex mb IIC T6 Gb
Ex tb IIIC T85°C Db
DNV 12.0078 X
ATENÇÃO - RISCO POTENCIAL
DE CARGA ELETROSTÁTICA
- VEJA INSTRUÇÕES
Page EN-3
Tabla de contenido
loading

Tabla de contenido