NOTE: It should be pointed out that this setting can be carried out using
password at the beginning of the command, or omitting the password in
case its number is already registered.
6
FUNCTIONS OF THE INPUTS
Command:
#TDXXYYY
XX - - Input number
YYY - Time
Function: :
It enables you to determine the minimum tine of continuous
stay of signal in the input, for detection of an event.
Parameter:
Number of input ranging from 01 to 02, detection time from
000 (immediate or pulse) to 999 seconds (time greater than zero).
• For the setting using a number already registered
Example 1:
For setting of the detection time of event in the input 1,
immediate or pulse: #TD01000
Example 2:
For setting the detection time of signal in the input 1, with
10-second retention detection applying input signal, send the following
command: #TD01010
• For setting using the password
Exemplo 1:
For setting of the detection time of event in the input 1,
immediate or pulse, sample password 0000: ?0000#TD01000
Exemplo 2:
For the setting of the detection time of signal in the input 1,
with 10-second retention detection applying input signal, sample password
0000: ?0000#TD01010
DETECTION OF EVENT IN THE INPUTS
DETECTION TIME OF INPUT SIGNAL
65
ENGLISH_