7
FUNCTIONS OF THE OUTPUTS
Command: #TPXXYYY
Function:
It enables you to determine the actuation time of the output
from 1 60 999 seconds, standard 1 second.
Parameter:
Output number from 01 to 02, Pulse time from 001 to 999
seconds.
• For the setting using a number already registered
Example:
For setting the pulse time in the output 1, as 5 seconds,
send the following command: #TP01005
• For setting using the password
Example:
For setting the pulse time in the output 1, as 5 seconds,
send the following command, sample password 0000: ?0000#TP01005
NOTE: Individual setting.
Command: *LXX
Function:
Actuates the output relay.
Parameter:
Number of input from 01 to 02.
• For command using a number already registered
Example:
For actuation of the output 1, send the following command: *L01
• For command using the password
Example:
For actuation of the output 1, sample password 0000: ?0000*L01
PULSE - PULSE TIME OF RELAY ACTUATION
ACTUATION OF THE OUTPUTS VIA SMS
67
ENGLISH_