TROUBLESHOOTING THE PRINTER

Status LED

When a printer fault occurs, the STATUS LED will flash. You can
identify the fault by the number of sequential flashes:
Sequence
*
*
*
** ** **
*** *** ***

Printing Problems

If the IR transmitter and receiver are not aligned, all the data may
not print. The infrared ports on the top of the Micro740 and on
front of the printer (below the MODE button) should be pointed
directly at each other. The maximum distance for reliable
transmission between the ports is 18 inches (45 cm).
If the analyzer is showing that it is sending data, press MENU to
cancel the print and turn off the printer. Charge the printer battery
for at least 15 minutes before attempting to print again. Align the
analyzer and printer IR transmitters and print again.
To realign, press MENU to cancel the print job. Verify alignment
between the analyzer and printer; then try to print the test results
again.
Make sure the printer is on. The printer shuts off after 2 minutes
of inactivity to conserve the battery. To turn the printer on, briefly
press the MODE button. The green STATUS light should turn on.
Make sure you are using the Midtronics printer provided with the
Micro740. Other printers may not be compatible.
Condition
Paper out
Thermal head too hot
Battery low
- 20 -
Solution
Fit new paper
Allow head to cool
Recharge printer
battery for 16 hours