38
38
A B B I N D U S T R I A L D R I V E S D C S 8 8 0 Q U I C K G U I D E
A B B I N D U S T R I A L D R I V E S D C S 8 8 0 Q U I C K G U I D E - 3 A D W 0 0 0 5 4 5 R 0 2 0 0
—
Parametergruppen
Zusammenfassung der Parametergruppen
Gruppe
01 Actual values
03 Input references
04 Warnings and faults
05 Diagnostics
06 Control and status words
07 System info
10 Standard DI, RO
11 Standard DIO, FI, FO
12 Standard AI
13 Standard AO
14 I/O extension module 1
15 I/O extension module 2
16 I/O extension module 3
19 I/O Operation mode
20 Start/Stop/Direction
21 Start/Stop mode
22 Speed reference selection
23 Speed reference ramp
24 Speed reference conditioning
25 Speed control
26 Torque reference chain
27 Armature current control
28 EMF and field current control
29 12-pulse/Hardparallel
30 Control limits
31 Fault functions and fault levels Externe Ereignisse, Abschaltschwelle.
32 Supervision
33 Generic timer & counter
35 Motor thermal protection
36 Load analyzer
37 User load curve
40 Process PID
42 Shared motion (2nd motor)
44 Mechanical brake control
45 Energy efficiency
46 Monitoring/Scaling settings
—
Regelkreise, meistgenutzte Signale
Die Optimierung des Regelkreises erfordert den Vergleich von Soll- und Istwerten
Eingangssignale
10.01 DI status
12.11 AI1 actual value
12.21 AI2 actual value
Inhalt
Volt, Ampere, U/min.
Feldbus, D2D.
Laufzeitzähler, Brückentemperatur.
Steuer-, Statusworte.
Informationen zu Hardware und
Firmware.
Digitaleingänge und Relaisausgänge
Analogeingänge.
Analogausgänge.
Drehzahl-/Drehmomentauswahl.
Digitaleingang, Hauptsteuerwort
Rampe, Austrudeln.
Analogeingang, Feldbus
Betriebsgrenzen des Antriebs.
Wartung.
Temperaturmessung, Definition der
Lastkurve.
Einstellungen zur
Drehzahlüberwachung,
Signalfilterung und allgemeine
Skalierungseinstellungen.
b0 Digitaleingang DI1
b1 Digitaleingang DI2
b2 Digitaleingang DI3
b3 Digitaleingang DI4
b4 Digitaleingang DI5
b5 Digitaleingang DI6
b15 Digitaleingang DIL
Analogeingang
Analogeingang
Gruppe
47 Data storage
49 Panel port communication
50 Fieldbus adapter (FBA)
51 FBA A settings
52 FBA A data in
53 FBA A data out
54 FBA B settings
55 FBA B data in
56 FBA B data out
58 Embedded fieldbus
60 DDCS Communication
61 D2D and DDCS transmit data
62 D2D and DDCS receive data
70 DCSLink Communication
74 ... 89 Application specific
groups
90 Feedback selection
91 Encoder module settings
92 Encoder 1 configuration
93 Encoder 2 configuration
94 OnBoard speed feedback
configuration
95 HW configuration
96 System
99 Motor data
Drehzahlregelkreis
23.03 Speed reference 7
90.01 Motor speed for control
Armature current control loop
27.02 Used current reference
27.05 Motor current
Inhalt
Datenspeicherparameter, die mit den
Quell- und Zieleinstellungen anderer
Parameter beschrieben und
ausgelesen werden können.
Vor-Ort Zeitüberschreitung.
Konfiguration
Feldbuskommunikation.
Feldbusadapter A.
Daten, die vom Feldbusadapter A an
den Master (z. B. SPS) gesendet
werden.
Vom Feldbus gelesene Daten.
Feldbusadapter B.
An den Feldbus gesendete Daten.
Vom Feldbus gelesene Daten.
D2D + DDCS-Port.
Definiert die Daten, die vom Antrieb
an die DDCS/D2D-Verbindung
gesendet werden.
Definiert die Daten, die von der DDCS/
D2D-Verbindung zum Antrieb
gesendet werden.
Externe Erweiterung, 12-Puls
Analogtacho, Impulsgeber ...
Konfiguration der Impulsgeber-
Schnittstellenmodule.
FENxx
FENxx
Analogtacho und OnBoard-
Impulsgeber der CON-H01.
Z. B. Typenschlüssel
Sprachauswahl; Zugriffsebenen; Mak-
roauswahl; Parameterspeicherung und
-wiederherstellung; Neustart der Rech-
nerkarte; Benutzerparametersätze;
Geräteauswahl; Datenloggerauslö-
sung; Parameter; Benutzersperre.
Motoreinstellungen, Selbsteinstellung
Drehzahlsollwert,
rampenförmig
Drehzahlistwert
Istwert