5.4.2
Connection to KMA 800 computer unit
The KMA 800 computer unit is located either in a pro-
tective housing on the wiring cabinet of the EPS or in a
KMA 822 in a trolley.
1. Connect the serial connecting cable 1 684 465 388
to serial interface X3 on the control device.
2. The other end of the connecting cable should be fit-
ted to the serial interface (COM 3) on the rear panel
of the KMA 800 computer unit.
i
The layout of the interfaces of the KMA800 computer
unit is described in the enclosed operator's manual
for the PC units.
!
The connecting cables should be routed such that
they do not cause an obstruction nor pose a hazard.
Robert Bosch GmbH
Electrical connection | CRS 845H | 45
5.4.3
Connection of EPS wiring cabinet power supply
!
When fitting connecting cable X4, make sure that
the banana plug is plugged into the correct socket in
the EPS switch cabinet.
!
Never connect or disconnect the power supply of
the CRE800 control device when the test bench
is switched on. This could destroy the PCB or the
control device.
i
The individual banana plugs are marked with special
identification sleeves (24V, 12V, 0V) on the cable
¶
Connect the connecting line X4 to the sockets of the
EPS 815 switch cabinet.
A10
RD
24V
RD
12V
BK
0V
X4
Fig. 42:
Connection of voltage supply
en
24V
12V
0V
EPS
24V
12V
|
1 689 978 535
2014-10-21