7 The fire put out and
power is off
automatically.
8 The blower still works
after the stove is cool and
fuel feed stops.
9 no enough heat wind
10. Showing "E5" on the
display
ELECTRICAL GENERATOR OPERATION
Your stove can be powered with a gas driven electrical generator.
However, the generator's electrical regulator may not be compatible with the stove's
The hopper is empty.
No fuel feed.
The fuel feed is too little.
low temperature switch
(30˚C) is wrong.
Set temperature is
reached
The low temperature
switch (30˚C) is broken.
Unqualified fuel
Blower speed is too low
or not running.
Heat exchange tubes or
flue pass are dirty.
Vent pipe is blocked
The door is opening or
seal needs to be replaced
The are some leakages
34
Adjust the combustion fan's speed
up
Call the dealer to reset the program
Put fuel into the hopper. refer to (2)
Lower the speed of combustion fan
Cool the stove at least 1 hour then
operate again or change the low
temperature switch (30˚C).
"ECO" its normal, waiting, after the
temperature is blow set on, it will
automatically switch on again
Change this switch.
Use the standard specially pellet.
Change the blower(Broken) or the
mother board is broken
Clean the heat exchange tubes or
flue pass.
Shut down the stove, check the
venting pipe
Close the door or change the seal
Check it and repair it.
Adjust the combustion fan's speed
up to offer more pressure in the
stove