Bauhaus Tossi 8 Instrucciones Para La Instalación, Uso Y Mantenimiento página 119

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

minutes)
B. For the second stage
C. Regarding to the last
stage
4. Feeding not properly
A. too much wood pellet
and cannot burned in time
B. The fire is off due to
little wood pellet can be
burned
5 After ignition the power
is off 15min later.
6 orange and lazy fire,
piled pellet, carbon on the
glass
about the connection
between motor and auger
No fuel in the hopper.
It is normal
Feed unit is blocked.
There is the problem
about the connection
between motor and auger
No fuel in the hopper.
The level of feeding
speed is too high
The level of feeding
speed is too low
Pellet feeder unit is off or
pellet is too little.
30˚C temperature switch
breaks or the connection
wires of switch loose.
Pressure Switch is broken
in the stove
Lack of air intake for
burning.
33
auger and motor loose or not.
Or the auger might jump out
Fill the fuel into the hopper.
Please be patient
Check the auger is blocked or not.
Check the fasten screw between
auger and motor loose or not.
Or the auger might jump out
Fill the fuel into the hopper.
Adjust the combustion fan's speed
up or Feeding quantity
Adjust the combustion fan's speed
Down or feeding quantity
Check the pellet feeder unit and
restart.
Check the connection wires or
change the 30˚C temperature switch.
Replace or repair the device
Clean the block in gate bar.
Check the door and window glass
gasket sealed or not.
Check the air intake pipe and
venting pipe blocked or not, and
clean it. Change to the big diameter
pipes if pipes are too long to affect
combustion.
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Tossi 10

Tabla de contenido