GB
at 60% duty cycle
at 25% duty cycle
Cable area mm
2 2 2 2
Fuse slow A
NB: The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. They may not be applicable in other countries: make sure that the cable area and fuse
sizes comply with the relevant national regulations.
PFC
The machine is equipped with Power Factor Correction converter and has
near--to--unity power factor. It complies with standard EN 61000--3--12:2005--04
Electromagnetic compatibility (EMC) -- Part 3--12: Limits for harmonic currents
produced by equipment connected to public low--voltage systems with input
current > 16 A and <= 75 A per phase.
Extension cord
If extension cord is needed it is recommended to use cord 3x2,5mm
length 50m.
Supply from power generators
The machine can be supplied from different types of generators. However, some
generators may not provide sufficient power for welding. The generators with AVR,
equivalent or better type of regulation with rated power 5,5...6,5 kW are
recommended to supply the Caddy
capacity. It is also possible to use generators with lower rated power, starting from
3,0kW, but in that case the machine setting must be proportionally limited. The
machine is protected against undervoltage. If the power supplied by the generator is
not sufficient, the welding is interrupted by the undervoltage protection. Especially
welding start could be disturbed. The generator should be replaced with a more
powerful one or welding parameters be decreased if operator finds the welding
process disturbed.
6
OPERATION
General safety regulations for the handling of the equipment can be found on
page 57. Read through before you start using the equipment!
WARNING!
Rotating parts can cause injury, take great care.
WARNING!
Lock the bobbin in order to prevent it from
sliding off the hub.
C200ie
12.8
23
3 x 1.5
16
R
Mig C200i semiautomatic welder within it's full
- - 61 - -
2
of maximum