OPERATING INSTRUCTIONS
CAUTION: Make sure the hose is not touching the smoker body.
Any fuel supply cylinder used must be constructed and marked in accordance with
for propane cylinders of the U.S. Department of Transportation (DOT) CFR 49, or the Standard for
Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods, CAN/CSA B339. The
appliance is to be used only with the 20-lb., vertical standing vapor withdrawal type tank and must
include a collar to protect the cylinder valve.
A. DO NOT store spare LP cylinders under or near the smoker.
B. NEVER
cylinder more than 80% full.
C. DO NOT store cylinder indoors.
WARNING: ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED
TO PREVENT FIRE, DAMAGE AND/OR INJURY.
WARNING: If instructions A, B and C are not followed exactly, a
injury may occur.
This smoker is designed to operate on LP gas only. The gas cylinder used must include a collar to
protect the cylinder valve. The cylinder supply system must be arranged for vapor withdrawal. Do
not allow dirt or foreign material to get into or onto tank connection when it is not attached to the fuel
supply system. Use the protective cap provided.
WARNING: ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED
TO PREVENT FIRE, DAMAGE AND/OR INJURY.
The cylinder outlet must have Type 1 gas connection termination in order to mate with gas hose
provided with smoker. The pressure regulator and hose assembly supplied by the manufacturer with
the appliance must be used. Replacement pressure regulators and hose assemblies must be those
by the appliance manufacturer.
This unit is not to be utilized with a non-self-contained LP-gas supply system.
Valve/pressure regulators are factory set to the correct operating pressures. No attempts should be
made to adjust these settings.
Disconnect the LP Tank
Make sure that the knob on the LP tank is clockwise
Hold the regulator in one hand, turn the coupling to the valve outlet counterclockwise
the connection by hand only. Do not use tools.
Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust
cap on the cylinder valve that is provided with the cylinder valve. Other types of caps or plugs may
result in leakage of propane.
Always hang the regulator on the tank retention wire while not in use, disconnected from the LP tank,
and when the unit has cooled.
to a full stop (CLOSED).
14