Piston in wrong position
Tool doesn't fire
-CAUTION-
Wait 10 seconds and then, if possible, remove the gas can and valve head from the tool before manipulating the
tool as described in the instructions below (*).
Nail jammed in the
fastener guide
Nail jammed in the
"guide" (steel part
of the magazine)
Tool cycling mechanism
jammed (no movement of Nail jammed under the button
nosepiece after lifting tool
away from work surface)
Gas can cannot be
removed
Printed: 07.07.2013 | Doc-Nr: PUB / 5069872 / 000 / 00
Tool is too hot
Gas can almost empty
Gas can almost empty
Valve head is defective
Valve head fitted incorrectly / not
fully seated
Gas can not inserted correctly in the
tool
Operating temperature too low
Ferromagnetic foreign objects
adhering to the magazine
Magazine is defective
Valve head does not dispense the
correct gas quantity
Electronics defective
Several nails driven on top of each
other
Nail has become jammed during
the driving operation
Piston in wrong position
Nail detector jammed (possibly
due to dirt or debris)
Trigger jammed in rearmost position
Loose nails / foreign objects
under the cover
Tool cycling mechanism jammed
Free the mechanism by pressing the reset
button
. Drive the next nail (the tool may
fire once without driving a nail after resett-
ing). Allow the tool to cool if necessary.
Use a new gas can
(fit the valve head to the new can).
Insert a new gas can.
Fit a new valve head on a new gas can.
Fit the valve head to the can correctly.
Insert the gas can in the tool correctly.
Use a gas can that has been warmed
to room temperature (~20°C / ~68°F)
Remove foreign objects from the
magazine.
Try using another magazine.
Remove the gas can and allow it to
cool or operate the valve head manually
several times (press the white plate toward
the valve head) until it functions correctly.
-WARNING-
Never point the nozzle toward persons, ani-
mals, naked flames or hot objects).
If electronics are defective, no
immediate remedy is possible. Have
the tool repaired at a Hilti repair center.
* Remove the magazine and nosepiece and
pull the nail out toward the front.
* Remove the nosepiece and tap the nail
back with a hammer and pin punch.
* Remove the magazine.
Remove the nail.
* See "Piston in wrong position"
* Remove magazine, remove nail.
-CAUTION-
Do not damage the button and nail detector
* Pull the nosepiece forward
by hand or use pliers.
* Bring the trigger into its outset
position (by hand or use pliers).
* Remove the magazine, remove
foreign objects. Have the tool
repaired at a Hilti repair center.
Remove the magazine. Remove the nail.
Open the cover of the gas can compartment
and press the valve head toward the outside,
in the direction of the arrow, until the valve
head is released from the can. Remove the
valve head and the gas can individually.
en