USER INSTRUCTI ONS - EN GLI SH
FALL CLEARANCE DIAGRAM
HLL
Deflection
System Height
Above Working
Surface
Lanyard Length
Total Fall-
Clearance Required
3.5 FT Lanyard
Deployment
Fall-Clearance
From Working
1FT Harness Stretch
Surface To Next
Lower Level
6 FT
5 FT To
Worker
Worker's
Height
D-Ring
3 FT
Safety Factor
7.0 CARE, MAINTENANCE AND STORAGE
CLEANING INSTRUCTIONS
Basic care of all Miller Fall Protection equipment will prolong the life of the unit and
will contribute toward the performance of its vital safety function. Proper storage and
maintenance after use are as important as cleansing the equipment of dirt, corrosives,
or contaminants. Storage areas should be clean, dry and free of exposure to fumes or
corrosive elements. Wipe off all surface dirt with a sponge dampened in plain water.
Squeeze the sponge dry. Dip the sponge in a mild solution of water and commercial
soap or detergent. Work up a thick lather, with a vigorous back and forth motion. Then
wipe dry with a clean cloth. Hang freely to dry, but away from excessive heat or steam.
MAINTENANCE/SERVICE
Servicing must only be carried out by a qualified person trained in the inspection
and replacement of the system. A record log of all servicing and inspection dates for
this system should be maintained by the company safety officer. This system and all
components must be withdrawn from service if subjected to fall arresting forces. Only
original Miller Fall Protection replacement parts are approved for use in this device.
Contact your Miller Fall Protection distributor or Miller Fall Protection Technical Service
department at 800.873.5242 if you have any questions.
STORAGE
Clean the components to remove any dirt, paint or other materials that may have
accumulated. Store in a clean, dry area when not in use.
11