Electrical diagram
100 / 110 / 220 / 240 Vac
50 / 60 Hz
Hydraulic connections diagram
* For salinity levels above 1500 ppm, please check with your distributor.
** Higher levels of hardness can reduce the service life and correct function of certain components.
***Maximum accumulation may vary depending on the model.
**** Flows can vary by up to 20% in function of the temperature, pressure and specific composition of the water to be treated.
***** Possible variations depending on the model chosen.
FAUCET
DRAIN
INLET
2. HOW THE EQUIPMENT WORKS
• The mains water to be treated is fed through the
equipment after passing through the pre-filtering
stage that incorporates a turbidity (S+C) and carbon
filte. During this filtering stage, chlorine, its deri-
vatives and other organic substance particles are
retained.
• The appliance incorporates a low pressure switch
(LPS) to protect pump from pressure drops in the
network.
• Water flow towards the appliance is controlled by
a solenoid valve (Si).
• After the filtering stage, water flows towards the
reverse osmosis membranes (M). The appliance in-
corporates a pump (P) to increase pressure. It is the
effect of the water pressure upon the membrane,
which makes the reverse osmosis possible.
• Water that is rejected or has excessive salt or
other dissolved substances flows towards the drain
outlet to be disposed of.
• Working cycles in a direct flow appliance are con-
trolled by a high pressure swift (HPS).
Technical information
PUMP
L
PSK
24 Vdc
260
FAUCET
DRAIN
INLET
LPS
HPS
R Pump
Q
P
MANUFACTURED BY:
PURICOM INDUSTRIAL WATER
CORPORATION (Taiwan)
DISTRIBUTED BY:
WATER LOGISTICS GROUP
Pol. Ind. L'Ametlla Park. C. Aiguafreda, 8.
08480 L'Ametlla del Vallès. Barcelona (España)
T. 902 305 310 F. +34 936 934 329
• The appliance has different functional and/or sa-
fety systems, managed by a state-of-the-art electro-
nic module:
• Electronic system for leakage detection (L).
When the system detects this condition, it bloc-
ks the system and emits an acoustic signal and
a light signal to inform about the situation. The
unit will remain blocked until the leakage sen-
sor is dry.
• Probe used to estimate the conductivity of
water produced, thus assessing the state of the
membrane and the components (Q). Press the
front button to measure the conductivity of wa-
ter produced.
• Automatic filter change warning, in order to
inform the user that proper maintenance must
be carried out to guarantee the quality of water
produced. The equipment must undergo a pro-
per maintenance.
• This appliance has built-in mixing valve. The
user will be able to regulate the salinity of su-
pplied water to the desired taste and/or local
regulations.
This regulation must be carried out while the
unit is producing water. To make the mixing
42
R
PSK
260
R Pump
Si