Technical Characteristics; Working Limits - GuTZZI direct flow Manual De Uso

Equipos de ósmosis inversa
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1. TECHNICAL CHARACTERISTICS

Water treatment
Use
Modifications due to reduction or contribution
Pressure (max. /min.)
TDS (max.)
Temperature (max. / min.)
Hardness (max.)
(*) For salinity levels above 1500 ppm, please check with your distributor.
(**) For maximum performance and longevity of components.
In the event of any queries in relation to installation, use or maintenance of this equipment, please contact
your distributor's technical assistance service (S.A.T).
2. PRIOR WARNINGS
Warning: This equipment IS NOT A WATER PURI-
FIER. In the event of the water to be treated co-
ming from a public water supply (and therefore
meeting current legislation requirements), this equip-
ment will substantially improve the water quality.
Warning: In the event of the water to be treated
not coming from a public water supply or from an
unknown source, a physico-chemical and bacteria
analysis of the water. Should be completed in order to
ensure the correct purification process and by applying
the appropriate techniques and equipment as neces-
sary PRIOR TO THE INSTALLATION of the equipment.
Please contact your distributor in order to receive advi-
ce on appropriate treatment.
Application
• Reverse osmosis
• Improves the drinking water's characteristics (meeting all European Directive on Water
for Human Consumption 98/83 requirements and its national transpositions in the
various EU member states).
• Water treatment via reverse osmosis is able to greatly reduce salt and other
concentrations.
• Minimum reduction* of specific compounds and parameters:
Sodium – 90 %
Calcium – 90%
Sulphates – 90%
Chloride – 90%
Total Hardness – 90%
Conductivity – 90%
(*) In function of the characteristics of the water to be treated.

Working limits

EQUIPMENT WITH PUMP · PUMP
32
6 bar (600 kPa)
1 bar (100 kPa)
1500 ppm
40ºC – 2ºC
15ºHF**
2.1 CONDITIONS FOR THE CORRECT WORKING OF
EQUIPMENT
• The system should not be used with hot water
(T>40ºC).
• The ambient temperature must be between 4º and
45ºC.
• For water with salinity concentration above 1500 ppm
please consult with your dealer.
• We recommend that the water to be treated should
be softened or with a maximum hardness level of 15
ºHF in order for your equipment to achieve maximum
performance.
• In the event of the water to be treated having a hard-
ness level in excess of 15 ºHF, the equipment's membra-
ne life and equipment performance may be affected.
Tabla de contenido
loading

Tabla de contenido