GuTZZI direct flow Manual De Uso página 34

Equipos de ósmosis inversa
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

purchase, or at a local recycling centre, indicating that
said equipment contains electric and electronic com-
ponents (model PUMP). The appropriate collection and
treatment of products, which no longer are to be used,
contributes to the preservation of natural resources
and avoids any potential public health risks.
5. INSTALLATION
The installation of your osmosis equipment
should be carried out by a suitably qualified
technician. Please read carefully the user
manual before use and consult with your
distributor in case of doubt.
Warning: Given that the equipment to be installed
will improve the quality of your drinking water, all
tools to be used in the installation process should
be clean, rust and grease free. Only use tools, which
are specifically designed for membrane tube cutting.
Please keep tools clean and disinfect them periodically.
Warning: The installation process should be ca-
rried out under appropriate hygienic conditions,
taking all necessary precautions in relation to ma-
terials and components that will come into contact with
water to be treated or consumed.
(For further information please contact your distributor).
Warning: Avoid external contamination of the
equipment through improper handling, using
gloves, sanitising gel and washing hands as often
as is necessary during the installation process, initial
operation and
equipment maintenance.
The most common installation location tends to be
under the kitchen sink unit or in an nearby cupboard.
Install the tap, the drain collar and entry inlet adapter
and connect the units respective connectors (5, 6 and
7).
5
6
40mm drain tube clamp
7
Adaptor and inlet water valve for connections
of 3/8"
Warning: Some of the installation accessories
may vary in function of the model and distribu-
tion region.
6. INITIAL OPERATION
6.1 CARBON FILTER RINSE
The elimination of carbon dust caused by the filters du-
ring transport and handling of the equipment is requi-
red. This dust should be eliminated as it may complete-
ly or partly obstruct the reverse osmosis membrane as
well as causing the equipment to malfunction.
To complete this process, disconnect the tube between
the outlet of the carbon pre-filter and the membrane
housing inlet (see 1 in sketch 8). Power the equipment
hydraulically and electrically and aim this tube towards
an external recipient or sink until the water runs clear.
Warning: Do not clean the carbon pre-filters
through the tap, as the carbon dust will penetrate
the equipment's components causing malfunc-
tion and/or reducing the service life of certain compo-
nents.
After washing the filters, leave all tubes and compo-
nents in their original position and connection points.
6.3. SANITISE THE EQUIPMENT
Sanitise the equipment according to the model and
procedure indicated by the manufacturer (see Saniti-
sing Procedure).
In the event of any queries, please consult with your
distributor.
6.4. SYSTEM STOP, START AND WATERTIGHTNESS
CHECK
Turn off the appliance's tap with the hydraulic and elec-
tric power on, and carry out a visual inspection of the
equipment ensuring no leakages occur (during approx.
1 minute).
In the event of the
pump failing to stop,
adjust the high pres-
sure switch setting
with a 2mm Allen
key until the pump
stops (12).
34
12
Tabla de contenido