DATA
SHEET
GUTZZI Direct Flow
1. TECHNICAL FEATURES
Water treatment
• Reverse osmosis
Use
• Improves the drinking water's characteristics (meeting all European Directive on
Water for Human Consumption 98/83 requirements and its national transpositions
in the various EU member states).
Modifications due to reduction or contribution
• Water treatment via reverse osmosis is able to greatly reduce salt and other
concentrations.
• Minimum reduction* of specific compounds and parameters:
Sodium – 90 %
Calcium – 90%
Sulphates – 90%
Chloride – 90%
Total Hardness – 90%
Conductivity – 90%
(*) Depending on the characteristics of the water to be treated (in the membrane outlet).
These values may vary in function of the type of post-filter used by the equipment and/or setting
of the mixing valve (where applicable).
Pressure (max. / min.)
TDS (max.)
Temperature (max. / min.)
Hardness (max.)
Control type
Safety lock
Dimensions (A x B x C)
Weight
Total tank volume
Entry connection
Drain connection
Tap connection
Wall adapter
Drain collar
Application
Working limits
6 bar (250 kPa)
1 bar (100 kPa)
1500 ppm
40ºC – 2ºC
15ºHF**
Technical Information
High pressure switch.
Inlet solenoid valve
Low pressure switch
Electronic leaking sensor.
Pressure limiter.
Water quality control.
Maintenance warning.
410 x 220 x 415 mm
12 Kg
-
3/8"
1/4"
3/8"
3/8" M-F *****
40mm drain tube clamp
40
A
C
B
ENTRADA DESAGÜE
GRIFO