8
PREFILTRATION
INLET
• Turn on the faucet the appliance should start working
and supplying water.
• Turn off the faucet and check if the appliance stops.
6.5. RINSING AND CLEANING
Turn on the equipment's tap and check the quality of
the water being dispensed with a conductivity tester or
TDS; check the reduction of salts obtained is sufficient
in relation to the water to be treated (15).
13
Warning: In the event of discovering that the wa-
ter dispensed does not adhere to current national
legislation, close the inlet valve, empty the equip-
ment with the tap, disconnect it from the electric mains
(PUMP model), and contact your technical assistance
service.
Finally, clean the interior and the bottom of the equi-
pment with disposable drying paper in order to remo-
ve any water, which may have been left, which would
block the system.
7. MAINTENANCE
Warning: Some of your unit's components, such as
the membrane, the pre-filters and the post-filters
are consumable items which have a limited lifetime.
Their duration will depend on the quality of the local
water, consumption, type of use and specific water con-
ditions such as extreme turbidity, high chlorine levels,
excessive iron content etc...
Warning: To guarantee the quality of the water
produced by your equipment, periodical mainte-
nance should be carried out.
1
MEMBRANE
MEMBRANE
• Pre-filter: At least once a year *
• Osmosis membrane: Every 3 years approx. (for
soft water (hardness <15ºHF))
• Sanitation: During the initial operation. At least
once a year in function of use. Each time access is
made with components in contact with the equi-
pment's water or if water has not been consumed
during more than one month.
*
In function of the expected consumption and the characteristics
of the water to be treated.
All maintenance should be carried out by qualified te-
chnicians who should handle the equipment properly,
as well as using original replacement parts in order to
maintain the equipment's characteristics, warranty,
equipment features as well as preserving the quality of
the water dispensed.
the warranty, as well as rendering invalid the equip-
ment's certifications.
An excess of any compound (total chlorine, turbidity, hard-
ness etc) may reduce the equipment's service life and cer-
tain components. This maintenance advice is only a guide.
Your distributor will estimate the life of the replacement
parts depending on the characteristics of the water to be
treated as well as the expected consumption in each case.
storage and transit. Take special hygiene measures
when removing said parts from their packaging as well
as during handling of the various components and con-
nectors.
35
Quality
probe
DRAIN
MEMBRANE
Recommended maintenance
Warning: The use of non-original replacement
parts, non-regulatory installation or initial opera-
tion, maintenance or improper use may invalidate
Warning: All replacement parts come in specially
designed individual packaging to ensure hygienic
Warning: Before dismantling the equipment, take
care to assure that you have all material neces-
sary for the required maintenance (read section