Model 366
BTU Rate
(1) Natural 15000, LP 12000 BTU
(2) Natural 18000, LP 15000 BTU
(3) Natural 15000, LP 12000 BTU
(4) Natural 18000, LP 15000 BTU
(5) Natural 15000, LP 12000 BTU
(6) Natural 18000, LP 15000 BTU
Model 364 with Grill
BTU Rate
(1)
Natural 15000, LP 12000 BTU
(2)
Natural 18000, LP 15000 BTU
(3)
Not applicable
(4)
Natural 15000, LP 12000 BTU
(5)
Natural 18000, LP 15000 BTU
Model 486 with Grill
LP Orifice size
105
(1) Natural 15000, LP 12000 BTU
115
(2) Natural 18000, LP 15000 BTU
105
(3) Natural 15000, LP 12000 BTU
115
(4) Natural 18000, LP 15000 BTU
105
(5) Not applicable
115
(6) Natural 15000, LP 12000 BTU
(7) Natural 18000, LP 15000 BTU
Model 486 with Griddle
LP Orifice size
105
115
(1) Natural 15000, LP 12000 BTU
(2) Natural 18000, LP 15000 BTU
105
(3) Natural 15000, LP 12000 BTU
115
(4) Natural 18000, LP 15000 BTU
(5) Not applicable
(6) Natural 15000, LP 12000 BTU
(7) Natural 18000, LP 15000 BTU
4. Perform a gas leakage test of each orifice and
BTU Rate
BTU Rate
associated supply tube fittings. See "Checking for
Gas Leaks" on page 11. Leak-checking should occur
after the orifice conversion is complete, and before
the burner is reassembled and tested.