Alliance Laundry Systems UWL035K12 Instalación Funcionamiento Mantenimiento página 56

Tabla de contenido
Especificaciones y dimensiones
Código
NOTA: Follow your local electrical codes. Use only copper conductors, rated for 90ºC [194°F] or higher, type
THHN or better. No more than three current carrying conductors per raceway. Contact your local Authority
having jurisdiction if you have questions. Circuit breakers should be UL 489 listed or better. Single phase cir-
cuit breakers for single phase machines only; three phase circuit breakers for all others.
Código
Q
N
Estándar
Calefac-
ción eléc-
trica
P
Estándar
Calefac-
ción eléc-
trica
NOTA: Follow your local electrical codes. Use only copper conductors, rated for 90ºC [194°F] or higher, type
THHN or better. No more than three current carrying conductors per raceway. Contact your local Authority
having jurisdiction if you have questions. Circuit breakers should be UL 489 listed or better. Single phase cir-
cuit breakers for single phase machines only; three phase circuit breakers for all others.
56
Modelos con capacidad de 100 libras
Designación de voltaje
Voltaje
Ciclo
Tabla 26
Modelos con capacidad de 125 libras
Designación de voltaje
Voltaje
Ciclo
200-240
50/60
440-480
50/60
380-415
50/60
Tabla 27
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Fase
Hilo
Fase
Hilo
3
3
3
3
3
3
Especificaciones
Amperios
a plena
Disyun-
carga
tor
Especificaciones
Amperios
a plena
Disyun-
carga
tor
12
16
11
16
74
80
11
16
65
80
F8423301COR3
mm2
mm2
2,5
2,5
16
2,5
16