CPX-FVDA-P2
Dismounting of the electronics module
Note
Incorrect handling can result in damage to the electronics module.
S Never pull the electronics module from the interlinking block when powered.
To avoid errors in mounting, both the interlinking block CPX-M-GE-EV-FVO and the
electronics module CPX-FVDA-P2 are mechanically coded. The coding prevents a
different module from being plugged into the interlinking block or the module from
being plugged into an incorrect interlinking block.
The plugs connected to the connection block may remain attached while dismount-
ing the connection block.
To dismount:
1. Switch off the operating and load voltage supplies.
2. Unscrew the screws aJ and carefully lift off the connection block 1 or 2
(
Fig. 1).
3. If required: Pull the electronics module 2 carefully off the contact rails.
46
Festo CPX-FVDA-P2-Z6 1209NH English