Tips And Recommendations For - SOMFY Irismo DC Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
2.3.3. Checking the direction of rotation (only for RTS version) (Fig G)
1) Press the Open button on the RTS control point:
a) If the motorised product opens (a), the direction of rotation is correct.
b) If the motorised product closes (b), the direction of rotation is incorrect: Move onto the next step.
2) Press the my button on the RTS control point until the motorised product moves: The direction of rotation has been modified.
3) Press the Open button on the RTS control point to check the direction of rotation.
2.3.4. Recording the RTS control point (only for RTS version) (Fig H)
Press the PROG button on the back of the control point until the motorised product moves. The remote control address is
permanently recorded.
2.3.5. Adjusting the Touch motion sensitivity (Fig I)
1) Press the Open and Close buttons of the RTS control point or the Open,Stop and Close buttons of the DCT setting tool simul-
taneously until the motorised product moves.
2) Press the Open and Close buttons simultaneously until the motorised product moves to switch from high sensitivity, to low
sensitivity, to no touch motion, and back to high sensitivity.
3) Press the my/Stop button until the motorised product moves to confirm the setting.
2.3.6. Adjusting the speed (Fig J)
1) Press the Open and my/Stop buttons simultaneously until the motorised product moves.
2) Press the Open button to increase the speed, and the Close button to decrease the speed.
There are 4 speed options: 12.5 cm/s (default speed) - 15 cm/s- 17.5 cm/s- 20 cm/s.
3) Press the my/Stop button until the motorised product moves to confirm the setting.
2.3.7. Dry contact ergonomics setting : Standard or 2 buttons sequencing (Fig K)
1) Press the Open,Stop and Close buttons of the DCT setting tool simultaneously until the motorised product moves.
2) Press the Stop and Close buttons of the DCT setting tool simultaneously until the motorised product moves to change the
ergonomics.
2.4. TIPS AND RECOMMENDATIONS FOR INSTALLATION
2.4.1. Questions about the Irismo mini ?
Observations
The motorised product does
not operate.
2.4.2. Re-setting the end limits
Readjusting the Open end limit (Fig L)
1) Press the Open button to move the motorised product to the end limit to be readjusted.
2) Press the Open and Close buttons of the RTS control point or the Open,Stop and Close buttons of the DCT setting tool
simultaneously until the motorised product moves.
3) Press the Open or Close button to move the motorised product to the new desired position.
4) To confirm the new end limit, press the my/Stop button until the motorised product moves.
Readjusting the Close end limit (Fig M)
1) Press the Close button to move the motorised product to the end limit to be readjusted.
2) Press the Open and Close buttons of the RTS control point or the Open,Stop and Close buttons of the DCT setting tool
simultaneously until the motorised product moves.
3) Press the Open or Close button to move the motorised product to the new desired position.
4) To confirm the new end limit, press the my/Stop button until the motorised product moves.
2.4.3. Erasing the control point from the memory of the motor (only for RTS version) (Fig N)
This reset deletes all the local control points, however the end limit settings and favourite position are retained.
To delete all the programmed control points, use a pin to press and hold the motor PROG button until the motorised product
moves twice.
All the control points are deleted.
Copyright © 2014 Somfy SAS. All rights reserved.
Possible causes
The wiring is incorrect.
The control point battery is weak.
The control point is not
compatible.
The control point used has not been
programmed into the motor.
Solutions
Check and reconnect the power supply
Check whether the battery is weak and
replace it if necessary.
Check for compatibility and replace the
control point if necessary.
Use a programmed control point or program
this control point.
EN
5
Tabla de contenido
loading

Tabla de contenido