Igniter - L.B.White Sentry ST60 Manual Del Propietário

Ocultar thumbs Ver también para Sentry ST60:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Igniter

The tip of the igniter is exposed to a harsh environment
consisting of high temperatures and combustion prod-
ucts. Periodic servicing is required.
A. REPLACEMENT
1. Remove igniter mounting screws. See Fig. 14.
2. Lift and pivot the igniter until it clears the burner.
See Fig. 15.
DO NOT FORCE OR BEND THE IGNITER
OR THE BURNER VANES DURING THE
IGNITER REMOVAL
FIG. 14
SCREWS
FIG. 15
BURNER VANES
Sentry Tube Heaters
3. Pull the ignition cable's rubber boot from the igniter.
B. MAINTENANCE
1. Ensure the gap is 1/8 in. See Fig. 16.
2. Clean the electrode and ground rod using emery
cloth.
3. Ensure the insulative base of the electrode is not
cracked.
FIG. 16
FIG. 16
ELECTRODE
ELECTRODE
ELECTRODE
Owner's Manual • Sentry
19
GAP
(1/8 IN.)
GROU
GROU
GROUND ROD