L.B.White Sentry ST060 Manual Del Usuario E Instrucciones

Calentadores de tubo radiante
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

View this manual online at www.lbwhite.com
Attention
The Sentry heater has been
designed, tested, and evaluated by
the L.B. White Company as a direct
gas fired radiant tube heater. The
heater is designed specifically for
the intended use of heating animal
confinement buildings only.
CHECK WITH YOUR LOCAL
FIRE SAFETY AUTHORITY,
YOUR LOCAL FUEL GAS
SUPPLIER, OR THE L.B.
WHITE COMPANY IF YOU
HAVE QUESTIONS
REGARDING APPLICATIONS.
www.lbwhite.com
SEE ASSEMBLY
INSTRUCTIONS
INSIDE
Please refer to important
elevation information on
inside cover.
WORLD PROVIDER - INNOVATIVE CLIMATE SOLUTIONS
411 Mason Street, Onalaska, WI 54650 • 800-345-7200 • 608-783-5691 • 608-783-6115 (fax) • www.lbwhite.com
Owner's Manual and Instructions
Sentry
Single or Two Stage
Radiant Tube Heaters
Congratulations!
You have purchased the finest agricultural building heater available.
Your new L.B. White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and welcome
any suggestions or comments you may have...contact us at 1-(800)-345-7200,
or email us at [email protected].
The herein installation instructions are the L.B. White Co. LLC
suggested recommendations and guidelines for temporary or
permanent installation of the L.B. White Co. LLC heaters. Local,
state, and electrical and safety code requirements supersede these
guidelines. In the absence of local codes, see page 7 for installa-
tion in the U.S. or Canada.
ST060*
ST080*
ST100
ST125
Propane Vapor Withdrawal or Natural Gas
*Single Stage only
NOTICE
SCAN THIS
with your smartphone or
visit http://goo.gl/yyKxJo to
view maintenance videos
for L.B.White heaters.
* Requires an app like QR Droid
for Android or for iPhone
60,000 Btuh
80,000 Btuh
100,000 Btuh
125,000 Btuh
loading

Resumen de contenidos para L.B.White Sentry ST060

  • Página 1 SCAN THIS INSTRUCTIONS with your smartphone or visit http://goo.gl/yyKxJo to INSIDE view maintenance videos for L.B.White heaters. Please refer to important * Requires an app like QR Droid elevation information on for Android or for iPhone inside cover. WORLD PROVIDER - INNOVATIVE CLIMATE SOLUTIONS...
  • Página 2 Sentry Tube Heaters TABLE OF CONTENTS Heater Specifications ......................4 General Information ......................5 Safe Clearance From Combustibles ................5 Safety Precautions ......................6 Inlet Air Requirements ....................9 General Installation Instructions ...................10 Start-Up Instructions .....................17 Shut-Down Instructions ....................17 Cleaning Instructions ....................18 Maintenance Instructions ....................19 General Service Instructions ..................19 Troubleshooting Guide ....................25 Electrical Connection and Ladder Diagram ..............29...
  • Página 3 Sentry Tube Heaters GENERAL HAZARD WARNING ■ FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN: — DEATH — SERIOUS BODILY INJURY OR BURNS — PROPERTY DAMAGE OR LOSS FROM FIRE OR EXPLOSION — ASPHYXIATION DUE TO LACK OF ADEQUATE AIR SUPPLY OR CARBON MONOXIDE POISONING —...
  • Página 4 Sentry Tube Heaters Specifications ST060 ST080 ST100 ST125 Available Tube Lengths (ft.) Maximum Input per Hour BTU/H 60,000 80,000 100,000 125,000 Minimum Input per Hour (Two Stage) 65,000 75,000 Fuel Consumption per Hour (Max.) LPG (lbs.) 4.63 5.79 NG (cu. ft.) Gas supply pressure acceptacle for the 13.5 / 11.0 MAX./...
  • Página 5 Sentry Tube Heaters General Information This owner’s manual includes all options and continuing expert training and knowledge of gas accessories commonly used on or with this heater. heaters and should not be attempted by anyone who However, depending on the configuration purchased, is not so qualified.
  • Página 6 Sentry Tube Heaters Fuel Gas Odor Odor Fading - No Odor Detected Propane gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks. If a gas leak occurs, you should be able to ■ Some people cannot smell well. Some people smell the fuel gas .
  • Página 7 Sentry Tube Heaters Attention - Critical Points to Remember! 2. All installations and applications of L.B. White ■ Propane gas and natural gas have a distinctive odor. Learn to recognize these odors. (Reference heaters must meet all relevant local, state and “Fuel Gas Odor”...
  • Página 8 If gas straight as possible. is smelled after system lock out has occurred, -- Contact L.B.White Co. if you have any questions immediately close all fuel supply valves. Do not regarding the installation of the heater.
  • Página 9 Sentry Tube Heaters FIG. 3 DRAWING INLET AIR FROM ATTIC Air inlet Ceiling screen flange 12 in. from Ensure inlet cap is inside of Air inlet unblocked by insulation. roof tube Inlet tube must be 12 in. min. above insulation A.
  • Página 10 Sentry Tube Heaters result in a possible fire or explosion causing 9. Check all connections for gas leaks using approved loss of products, building or even life. A properly gas leak detectors. Gas leak testing is performed as installed sediment trap will keep foreign materials follows: from entering the gas valve and protect the safe WARNING...
  • Página 11 BURNER DISCHARGE Sentry Tube Heaters FIG. 6 FIG. 6 Initial Setup BURNER BOX BURNER BOX HANGING CHAINS HANGING CHA 1. Plan the installation. Determine location for the heater to optimize its heat pattern, keeping in mind cooler regions in the house (end walls, and curtains) and HANGING CHAIN DISTANCES clearances to combustibles.
  • Página 12 Sentry Tube Heaters 3. Slide on hangers and connect to chains. 4. Connect and hang remaining tubes. Follow the procedures given in Step 2. 5. The tube assembly should be either hung level, or with a downward slope away from the burner box not exceeding 1 in.
  • Página 13 Sentry Tube Heaters Installing Reflectors & Supports Refer to Fig. 8 for the following instructions: 4. Repeat Steps 3 for remaining reflectors. 1. Attach end cap to one end of the first reflector. Use 5. Install a support hanger at the end of the reflector near- the 4 U-clips to secure it to the relector.
  • Página 14 Sentry Tube Heaters Air Turbulation Strips Sediment Trap Assembly & Exhaust Vent Assemble the tee, nipple, and cap to the nipple at the gas inlet of heater. See Fig. 10. Use a wrench to hold the pipe nipple when installing the sediment trap. When installing the air turbulators, make Tighten securely.
  • Página 15 Sentry Tube Heaters Temperature Sensor Location 5 FT. FROM CENTER OF TUBE TO SENSOR LOCATION SENSOR LOCATED ABOVE SIDEWALL ANIMAL HEIGHT FLOOR SENSOR LOCATION FROM BURNER BOX 10 FT. SENSOR LOCATED ABOVE ANIMAL HEIGHT FLOOR Heater Controls Heaters with Two Stage Gas Control Valves WARNING Heaters with two stage gas controls are wired to start up Electrical Shock Hazard...
  • Página 16 Sentry Tube Heaters TRANSFORMER GREEN YELLOW YELLOW BLUE WIRE NUT BLACK GREEN WHITE WIRE NUT YELLOW TO TERMINAL "W" ON IGNITION CONTROL WIRE NUT TO GAS CONTROL VALVE TO HIGH HEAT L.E.D. 2. Building Controller Connections - Remove wire nut at orange, yellow and red wires - Connect controller contacts as shown.
  • Página 17 Sentry Tube Heaters Start-Up Instructions FIG. 13 Follow steps 1 - 6 on initial start-up after heater installation. For normal start-up, set building control RED FAULT LIGHT thermostat above room temperature. The heater will start. GREEN ON 1. Open all manual fuel supply valves and check GREEN HIGH HEAT (2-STAGE ONLY) for gas leaks using approved leak detectors.
  • Página 18 Sentry Tube Heaters Cleaning Instructions WARNING This heater may be washed only on its external WARNING areas provided: Fire, Burn and Explosion Hazard ■ The burner box is disconnected from the ■ This heater contains electrical and mechanical electrical supply. components in the gas management, safety and ■...
  • Página 19 Sentry Tube Heaters Maintenance Instructions 3. Regulators can wear out and function improperly. Have your gas supplier check the date codes on all regulators installed and check delivery pressures Before Each Use: to the appliance to make sure that the regulator is suitable for continued use.
  • Página 20 Sentry Tube Heaters Igniter FIG. 15 The tip of the igniter is exposed to a harsh environment consisting of high temperatures and combustion products. Periodic servicing is required. A. REPLACEMENT 1. Remove the 4 bolts from the burner tube See Fig 14. 3.
  • Página 21 Sentry Tube Heaters Motor and Fan Assembly Air differential switch: The air differential switch is a normally open, critical safety device. Its purpose is to prove to the ignition A. Motor/Fan wheel removal. control that there is a sufficient difference in pressure 1.
  • Página 22 Sentry Tube Heaters Gas Control Valve FIG. 22 (SINGLE STAGE SHOWN) 1. Remove the hose from the sediment trap 2. Remove the two (2) nuts that secure the gas control valve’s mounting bracket to the center partition of the burner box. See Fig. 20. FIG.
  • Página 23 Sentry Tube Heaters Gas Pressure Checks 4. Remove either the inlet or outlet pressure tap. See Fig. 25. (Single stage valve shown) FIG. 25 OUTLET INLET PRESSURE PRESSURE TAP ■ The following is a typical procedure to be followed in checking gas pressures. ■...
  • Página 24 Sentry Tube Heaters specified on the dataplate? If so, then no further checking or adjustment is required. Proceed to section C. 3. If the inlet pressures do not agree with that specified on the dataplate, then the regulator controlling gas pressure to the heater requires adjustment.
  • Página 25 Sentry Tube Heaters Troubleshooting A flashing light indicates a problem. The flash pattern will be followed by a pause and then a Information repeat of the flash pattern until the problem is corrected. Refer to the tables below to identify what page to refer READ THIS ENTIRE SECTION BEFORE to when troubleshooting any problems.
  • Página 26 Sentry Tube Heaters Owner’s Manual • Sentry...
  • Página 27 Sentry Tube Heaters Owner’s Manual • Sentry...
  • Página 28 Sentry Tube Heaters Owner’s Manual • Sentry...
  • Página 29 Sentry Tube Heaters Electrical Connection and Ladder Diagram Owner’s Manual • Sentry...
  • Página 30 Sentry Tube Heaters Service Parts Identification Schematic - Tube/Reflector Owner’s Manual • Sentry...
  • Página 31 Sentry Tube Heaters Parts List - Tube/Reflector Item Description Part # Air turbulation strip 572892 Vent cap 573970 Tube, calorized, 4 in. x 10 ft., with clamp 573010 Tube, stainless steel, 4 in. x 10 ft. w/clamp 573387 Clamp, 4 in. round, SS 574225 Hanger, 4 in.
  • Página 32 Sentry Tube Heaters Service Parts Identification Schematic - Burner Box Owner’s Manual • Sentry...
  • Página 33 Sentry Tube Heaters Parts List - Burner Box Item Description ST60/ST80 ST100/ST125 Latches and strike 573775 Red LED 573769 Green LED 573770 **Green LED, High Heat 2-Stage ONLY 574159 **Wire harness kit 574219 Ignitor 574220 Ignition cable 572847 Tube, air differential pressure switch 572883 Air differential pressure switch 574489...
  • Página 34 Sentry Tube Heaters Manual Rev./Changes Date Rev. Revision Change Description 8/16/2023 Released Owner’s Manual • Sentry...
  • Página 35 If a product has not been incidental or consequential damages, so the above registered with L.B.White, a copy of the bill of sale limitation or exclusion may not apply to you. This warranty will be required to establish warranty qualification.
  • Página 36 EN EL INTERIOR http://goo.gl/yyKxJo para para ver videos de mantenimiento de los Consulte la información im- calefactores L.B.White. portante sobre elevación en la * Necesita una aplicación como QR portada interna. Droid para Android o para iPhone PROVEEDOR DE SOLUCIONES CLIMÁTICAS INNOVADORAS...
  • Página 37 Calefactores de tubo radiante Sentry ÍNDICE Especificaciones del calefactor ..................4 Información general ......................5 Distancia de seguridad desde los combustibles .............5 Precauciones de seguridad ....................6 Requisitos de entrada de aire ..................9 Instrucciones generales de instalación .................10 Instrucciones de puesta en marcha ................17 Instrucciones de apagado ....................17 Instrucciones de limpieza .....................18 Instrucciones de mantenimiento ...................19...
  • Página 38 Calefactores de tubo radiante Sentry ADVERTENCIA GENERAL ■ SI NO SE CONTEMPLAN LAS PRECAUCIONES E INSTRUCCIONES SUMINISTRADAS CON ESTE CALEFACTOR, PUEDE OCURRIR LO SIGUIENTE: — LA MUERTE — QUEMADURAS O LESIONES GRAVES — DAÑOS O PÉRDIDAS MATERIALES POR INCENDIO O EXPLOSIÓN —...
  • Página 39 Calefactores de tubo radiante Sentry Especificaciones ST060 ST080 ST100 ST125 Longitudes disponibles de tubos (pies) Entrada máxima por hora BTU/H 60,000 80,000 100,000 125,000 Entrada mínima por hora (dos etapas) 65,000 75,000 Consumo de combustible por hora (máx.) GPL (lb) 4.63 5.79 GN (pies cúbicos)
  • Página 40 Calefactores de tubo radiante Sentry Información general Este manual del usuario incluye todas las opciones La instalación de la línea de suministro de gas y la y accesorios que se utilizan regularmente en o con reparación, la instalación y el mantenimiento del este calefactor.
  • Página 41 Calefactores de tubo radiante Sentry Olor a gas combustible El olor se disipa; no se detecta olor El gas propano y el gas natural contienen aromatizantes artificiales agregados específicamente ■ Algunas personas no tienen buen olfato. No para la detección de fugas de gas combustible. pueden percibir el olor del químico artificial Si se produce una pérdida de gas, debería ser capaz agregado al gas propano o natural.
  • Página 42 Calefactores de tubo radiante Sentry ¡Atención - Puntos críti- cos que debe recordar! b. Para ser una persona calificada en hacer instalaciones de gas, usted debe tener suficiente ■ El gas propano y el gas natural tienen un olor capacitación y experiencia para manejar todos característico.
  • Página 43 Calefactores de tubo radiante Sentry 13. Este calefactor está equipado con un enchufe 6. Por seguridad, este calefactor está equipado de tres clavijas (conexión a tierra) para brindar con un interruptor de presión de aire diferencial. protección contra el riesgo de descargas Nunca haga funcionar el calefactor si algún eléctricas, y se debe conectar directamente a un dispositivo de seguridad se ha desactivado.
  • Página 44 -- Consulte las instrucciones de los requisitos de se permiten curvas de más de 1 a 90º. la entrada de aire. -- Comuníquese con L.B.White Co. si tiene ■ La falta de una entrada de aire fresco puede preguntas sobre la instalación de este calefactor.
  • Página 45 Calefactores de tubo radiante Sentry Instrucciones generales de instalación 1. Lea todas las precauciones de seguridad y siga las 8. Siempre use un compuesto de junta de recomendaciones de L.B. White cuando instale este tuberías que sea resistente al gas licuado de calefactor.
  • Página 46 Calefactores de tubo radiante Sentry 17. Cualquier defecto que halle en la realización de -- Ajuste la conexión de gas según sea necesario para alguno de los procedimientos de mantenimiento detener la fuga. debe eliminarse y las partes defectuosas deben -- Si fuera necesario, reemplace las piezas o compo- reemplazarse de inmediato.
  • Página 47 OPEN EYE HOOKS IN LINE WITH Hang the burner box. See Fig. 5. Maintain clearances TIGHTEN HOOKS EYE BOLTS ON to combustibles as shown in Fig. 1. SECURELY BURNER BOX From the burner box chain, measure the distances shown in Fig. 6. Aligning to the center of the burner Calefactores de tubo radiante Sentry box discharge, hang chains at these points, using open eye hooks.
  • Página 48 Calefactores de tubo radiante Sentry FIG. 7 COLOQUE LAS ABRAZADERA DE MANERA PAREJA ABRAZADERA PERNOS ARRIBA SOLDADURA DE TUBO NO ESTAMPADO COSTURA HACIA ABAJO EXTREMO DEL TUBO INSTALACIÓN AÉREA ESTAMPADO TUBO EN LA CAJA ABRAZADERA PERCHA THIS NOT THIS ASÍ NO ASÍ...
  • Página 49 Calefactores de tubo radiante Sentry Instalación de reflectores y soportes Consulte la FIG. 8 para las siguientes instrucciones: 4. Repita los pasos 3 para los demás reflectores. 1. Coloque la tapa del extremo en un extremo del primer 5. Instale una percha de soporte en el extremo del reflector.
  • Página 50 Calefactores de tubo radiante Sentry Tiras de turbulencia Conjunto del colector de de aire y ventilación sedimentos Monte la T, el niple y la tuerca en el niple en la Ensamble las tiras e insertarlas en el entrada de gas del calefactor. Consulte la Fig. 10. Use último tubo (vea la Fig.
  • Página 51 Calefactores de tubo radiante Sentry Ubicación del sensor de temperatura 5 PIES DESDE EL CENTRO DEL TUBO HASTA LA UBICACIÓN DEL SENSOR SENSOR LOCALIZADO SOBRE SIDEWALL LA ALTURA ANIMAL EL PISO UBICACIÓN DEL SENSOR DESDE LA CAJA DE QUEMADORES 10 PIES SENSOR LOCALIZADO SOBRE LA ALTURA ANIMAL EL PISO...
  • Página 52 Calefactores de tubo radiante Sentry TRANSFORMADOR VERDE AMARILLO AMARILLO AZUL TUERCA DE TERMINAL NEGRO ROJO VERDE ALTO BAJA BLANCO TUERCA DE TERMINAL AMARILLO AL TERMINAL "W" SOBRE CONTROL DE ENCENDIDO ROJO TUERCA DE TERMINAL ROJO A LA VÁLVULA DE CONTROL DE GAS ROJO AL CALOR ALTO L.E.D.
  • Página 53 Calefactores de tubo radiante Sentry Instrucciones de puesta 4. En una llamada de calor, el motor arrancará y funcionará durante en marcha 5. Segundos y la luz verde ON se encenderá. losLa Para el encendido inicial, siga los pasos 1 a 6 luz verde High Heat se encenderá...
  • Página 54 Calefactores de tubo radiante Sentry c. Cuando lave con agua, no rocíe agua en la ADVERTENCIA caja del quemador ni los tubos. Lea y obedezca Peligro de incendio, quemaduras y las advertencias que se incluyen en estas explosión Instrucciones de limpieza. La misma advertencia ■...
  • Página 55 Calefactores de tubo radiante Sentry Instrucciones de 3. Los reguladores se pueden desgastar y pueden no funcionar adecuadamente. Pida a su proveedor de mantenimiento gas que verifique los códigos de fecha que figuran en todos los reguladores instalados y las presiones Antes de cada uso: que llegan al aparato para asegurarse de que el regulador sea adecuado para un uso continuo.
  • Página 56 Calefactores de tubo radiante Sentry Encendedor FIG. 15 La punta del encendedor está expuesta a un arduo ambiente con altas temperaturas y productos de combustión. Se requiere el mantenimiento periódico. A. REEMPLAZO 1. Quite los 4 pernos del tubo del quemador. Vea la 3.
  • Página 57 Calefactores de tubo radiante Sentry Interruptor de diferencial de aire: Conjunto del motor El interruptor del diferencial de aire es un dispositivo de seguridad crítico, comúnmente abierto. Su objetivo y el ventilador es probar al control de encendido que hay una diferencia suficiente de presión dentro de la caja de quemadores antes de que el control de encendido A.
  • Página 58 Calefactores de tubo radiante Sentry Transformador Válvula de control de gas El transformador (Fig. 22) reduce el voltaje de SE MUESTRA UNA ETAPA suministro de energía principal a 24 V de CA. El voltaje 1. Quite la manguera de la trampa de sedimentos. 24 V de CA se envía directamente al controlador de encendido.
  • Página 59 35 pulg. de columna de de aire. agua (también se puede pedira a W: 24 V de CA del transformador al control. (sin este L.B.White, número de pieza 00764) voltaje, el control de encendido no funcionará) Buje, 1/2.x1/8 pulgadas. FS: sin terminal.
  • Página 60 Calefactores de tubo radiante Sentry 4. Si la presión de entrada es correcta, pero la presión 3. Abra el panel de acceso a la caja del quemador. del colector del quemador no concuerda con la que se especifica en la placa de datos, entonces se 4.
  • Página 61 Calefactores de tubo radiante Sentry Un destello de luz indica un problema. Información de El patrón de parpadeo será seguido de una pausa y luego resolución de problemas la repetición del patrón de destellos, hasta que se corrija el problema. En las tablas siguientes, verá qué página debe LEA TODA ESTA SECCIÓN ANTES DE COMENZAR A consultar para la resolución de problemas.
  • Página 62 Calefactores de tubo radiante Sentry Manual del usuario • Sentry...
  • Página 63 Calefactores de tubo radiante Sentry Manual del usuario • Sentry...
  • Página 64 Calefactores de tubo radiante Sentry Manual del usuario • Sentry...
  • Página 65 Calefactores de tubo radiante Sentry Conexión eléctrica y diagrama de escalera Manual del usuario • Sentry...
  • Página 66 Calefactores de tubo radiante Sentry Esquema de identificación de piezas de servicio: tubos y reflector Manual del usuario • Sentry...
  • Página 67 Calefactores de tubo radiante Sentry Lista de peizas - Tubo/Reflector Número Descripción de pieza Ítem Tira de turbulencia de aire 572892 Tapa de ventilación 573970 Tubo, cal’orica, de 4 in x 10 ft, con abrazadera 573010 Tubo, acero inoxidable, 4 pulgadas x 10 pies, con abrazadera 573387 Abrazadera, redondo de 4 pulgadas 574225...
  • Página 68 Calefactores de tubo radiante Sentry Esquema de identificación de piezas de servicio - Caja de quemador Manual del usuario • Sentry...
  • Página 69 Calefactores de tubo radiante Sentry Lista de piezas - Caja de quemador Ítem Descripción Número de pieza Pestillos y golpe 573775 Luz LED roja 573769 Luz LED verde 573770 **LED verde, temperatura alta ÚNICAMENTE de 2 etapas 574159 12** ** Mazo de cables 13** 574219 Encendedor con soporte...
  • Página 70 Política de garantía CALEFACTOR o emergentes directa o indirectamente en relación con L.B. White Company, LLC garantiza que las piezas la venta, la manipulación o el uso del equipo. En todo de su calefactor estarán libres de defectos en los caso, la responsabilidad de L.B.

Este manual también es adecuado para:

Sentry st080Sentry st100Sentry st125