Cebora ARCO Manual De Instrucciones página 107

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Code
Type
79
[W]
Combined with gas console Item 465.01
indicates that shielding gas pressure is high.
81
[E]
Gas kit not present in combination with Kit Item
436.
84
[W]
Quality control option error
86
[E]
Problems regulating the plasma gas flow.
Combined with gas console Item 465.01
87
[E]
Problems regulating the shielding gas flow.
Combined with gas console Item 465.01.
90
[W]
CNC not ready. In robotised applications with
connection to interface Items 448, 428.XX or
direct connection to CNC.
95
[W]
Bluetooth mask not connected
99
[E]
Machine is powering down.
Error Description
Action
Check the pressure entering the shielding
channel. If the problem persists, contact
technical assistance.
Make sure that gas Kit Item 436 is correctly
connected. Switch the power source on and
off. If the problem persists, contact technical
assistance.
Check the parameters set are correct.
Check there are no obstructions in the plasma
gas pipes.
Test the channel using the appropriate test
command. Check the cylinder inlet pressure,
because the desired flow cannot be regulated
if it is too low. If the problem persists, contact
technical assistance.
Check there are no obstructions in the shielding
gas pipes.
Test the channel using the appropriate test
command. Check the cylinder inlet pressure,
because the desired flow cannot be regulated
if it is too low. If the problem persists, contact
technical assistance.
Check connection to power source CN2, check
the robot ready signal is present on the interface
or CNC. Check the accuracy of robot interface
parameters, check the interface and power
source terminal DIP switches. Turn off and
on. If the problem persists, contact technical
assistance.
Check the mask battery. Connect the mask to the
power source in accordance with the procedure
described in the relevant manual. If the problem
persists, contact technical assistance.
Wait for the power source to power down. During
this stage, do not turn the power source back on
by turning the mains switch because the power
source would lock. Turn off the machine, wait for
at least 30 seconds and turn back on.