3�9
Description of display
WinTIG line power sources are equipped with a 7" LCD display (A) Fig. 1 and resistive touchscreen that can be used
even when wearing welding gloves.
The main screen is subdivided into sectors (S, R, Q...T see fig. 4) and each of these accepts a touch command.
description of the individual display sectors is given below.
S
R
Q
P
Fig. 4
Sector
Description
S
Main screen status bar
R
Main welding parameter settings menu
Q
Selection of welding process type TIG DC, TIG DC APC, TIG XP, TIG AC, MIX AC, MMA, MMA AC
Plasma Welding, TIG Cold Wire. (*)
P
Selection of start type, two stroke, four stroke, three level, four level.(**)
O
Selection of ignition type, HF, Lift, Evo Lift.
N
Selection of DC pulse parameters, duty cycle frequency, second current level.
V
Selection of AC process, frequency, horizontal balancing, vertical balancing, penetration waveform type
and cleaning parameters.
M
Main menu for machine process setup, process parameters, accessories and settings.
Z
MIX AC process parameter settings menu.
I
JOB management menu
T
Gas test and motor speed menu.
(*) If robot operating mode is activated, the TIG DC APC, MMA and MMA AC processes are not available.
(**) If robot operating mode is activated, only 2 stroke starting is available.
V
O
N
During start-up, for 5 seconds the display presents all the information
regarding the machine, the serial number, the software version, when
the software was updated, the options installed and the IP address.
The display then presents the main screen (factory setting).
T
I
Z
M
A
65/107