Siemens 1FK6 Instrucciones De Servicio página 247

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

08.2009
P060 = 3
P071 = ?
P095 = ?
P095 = 1
2
P096 = ?
P097 = ?
P099 = ?
P130 = ?
0, 1, 2, 3, 5, 6, 7
4
P147.1 = ?
Siemens AG
6SE7087-8JP50
SIMOVERT MASTERDRIVES
Select "Quick Parameterization" menu
Input of unit line voltage in V
AC Units: RMS value of AC voltage
DC Units: DC link voltage
Input of motor type
0: No motor connected
1: 1FT6/1FK6 synchronous servo-motor
5
2: 1PH7(=1PA6)/1PL6/1PH4 induction servo-motor
5: Torque motor 1FW3
Input the code number for the connected 1FK6/1FT6 motor
(For list see Chapter 8.8)
Input the code number for the connected 1PH7(=1PA6),
1PH4, 1PL6 motor (For list see Chapter 8.8)
Input the code number for the connected 1FW3 motor
(For list see Chapter 8.8)
Select motor encoder
0: automatic encoder detection
1: 2-pole resolver
2: Resolver with pole pair number of motor
3: Encoder 2048/rev.
4: Multiturn encoder 2048/rev.
5: Pulse encoder 1024/rev.
7: Encoders without C/D track 2048/rev (SW V1.30 and
later)
The absolute initial position is not set on encoders without
a C/D track. These can only be used on asynchronous
machines. The position is corrected via a zero pulse (if
connected).
1PA6, 1PL6, 1PH4 and 1PH7 asynchronous motors with
encoder:
These motors are normally supplied with an ERN1381
encoder without C/D track.
Selection of a multiturn enocder
1: EQN1325 (2048 lines)
2: ECN1313 (2048 lines)
6: EnDat
7: EQI1325 (32 lines)
8: EQN1125 (Heidenhain) EnDat
9: ECN1113 (Heidenhain) EnDat
Operating Instructions
Parameterization
8-27

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

1fk71ft61fs6

Tabla de contenido