1.5

THE GENERATOR

Figure 1.1 – 7kW, Single Cylinder, LV-432 Engine (door
Oil Filter
Air Filter
Exhaust
Enclosure
Base
Data label Sample
removed)
Data Label
Control Panel
(see sample)
Circuit Breaker
Battery
Ground Lug
Fuel Regulator
1.6
1.6.1
Rated Voltage ........................................................................240
Rated Maximum Load Current (Amps) at 240 Volts (LP)* .....29.2
Main Circuit Breaker ........................................................30 Amp
Transfer Switch Load Center Circuits** 30A, 240V ....................1
30A, 240V ................................................................................1
20A, 120V ..................................................................................3
15A, 120V ................................................................................3
Phase .......................................................................................1
Number of Rotor Poles ..............................................................2
Rated AC Frequency ...........................................................60 Hz
Battery Requirement ............................... Group 26R, 12 Volts and
Fuel Inlet
Weight (unit only in lbs.) .......................................................225
Enclosure ................................................................... Composite
Normal Operating Range: This unit is tested in accordance to UL
2200 standards with an operating temperature of -20 °F (-29 °C)
to 122 °F. (50 °C). For areas where temperatures fall below 32 °F
(0 °C), a cold weather kit is highly recommended. When operated
above 77º F (25º C) there may be a decrease in engine power.
(Please reference the engine specifications section).
These generators are rated in accordance with UL2200, Safety
Standard for Stationary Engine Generator Assemblies; and CSA-
C22.2 No. 100-04 Standard for Motors and Generators.
* Natural Gas ratings will depend on specific fuel Btu content. Typical derates are
between 10-20% off the LP gas rating.
** Circuits to be moved must be protected by same size breaker. For example,
a 15 amp circuit in the main panel must be a 15 amp circuit in the transfer
switch.
1.6.2
Type of Engine ..............................................................OHV-432
Number of Cylinders .................................................................1
Rated Horsepower @ 3,600 rpm* .......................................14.8
Displacement .................................................................... 432cc
Cylinder Block ................................ Aluminum w/Cast Iron Sleeve
Valve Arrangement .............................................Overhead Valves
Ignition System .........................................Solid-state w/Magneto
Recommended Spark Plug ............................................. RC12YC
Spark Plug Gap .........................................0.76 mm (0.030 inch)
Compression Ratio ..............................................................8.2:1
Starter ............................................................................ 12 VDC
Oil Capacity Including Filter........................Approx. 1.1 Qts (1.0L)
Recommended Oil Filter ...................................... Part # 0H9039
Recommended Air Filter ...................................... Part # 0H6104
Operating RPM ...................................................................3,600
* Engine power is subject to and limited by such factors as fuel Btu content,
ambient temperature and altitude. Engine power decreases about 3.5 percent
for each 1,000 feet above sea level; and also will decrease about 1 percent for
each 6 C (10 F) above 16 C (60 F) ambient temperature.
General Information

SPECIFICATIONS

GENERATOR
ENGINE
525 CCA Minimum