koban KDP3 360 Manual De Usuario página 29

Detector de presencia empotrable
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

• Fix the detector head on power box by inserting its four non-dropping
screws into the corresponding screw holes, then cover up the decorative
frame (See FIG.11).
• Restore the power supply.
Flush mount with power box cap KDP3/5 (Optional purchase)
• To install detector, please drill a hole with diameter of 65mm on ceiling
board and keep the power cable outside. Please strip off 6 - 8mm of cable
sheathing for wiring (See FIG.14).
Φ=65
Drill a hole with
Φ=65mm on the
ceiling
• Use screwdriver to break the rubber gasket on KDP3/5, then feed cables
through it (See FIG.15).
• Please refer to illustration of FIG.5 - FIG.10 for correct wiring and then
screw the KDP3/5 tightly.
Rubber gasket
Cable entry
www.grupotemper.com
6 - 8mm
FIG.14
Non-dropping
screw
Power box cap
KDP3/5
FIG.15
KDP3 360
Presence detector
30 - 35mm
Instructions manual |
29

Capítulos

Tabla de contenido
loading

Tabla de contenido