Response Times Of The Safety Switch; Tab. 7: Response Times Of The In4000 Standard Safety Switches - SICK Standard IN4000 Instrucciones De Servicio

Ocultar thumbs Ver también para Standard IN4000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Operating Instructions
IN4000 Standard
Tab. 7: Response
times of the
IN4000 Standard
safety switches
8010934/ZWG9/2018-07-26
Subject to change without notice
Product description
3.6

Response times of the safety switch

Response time on safety request
(removal from the enable zone)
Response time on approach to
the near range zone (non-safety-
2)
relevant zone)
Response time on approach to
the enable zone (enable time)
Signal delay on cascading
sensors (per sensor)
Ready delay time on applying TE
(per sensor)
Error response time on safety-
4)
relevant errors
Permissible duration in the near
range
Delay time for the activation of
the adjustment mode
Dwell time in the state with
activation removed (≥ 30 mm) for
the return to the operating mode
1)
During this time the output is switched off (Logical "0").
2)
See Fig. 3.
3)
From this point in time the PSDI input signal is forwarded to
the output with a time delay.
4)
See Fig. 3.
5)
See section 5.3.
© SICK AG • Germany • All rights reserved
T2 + 20 ms
T
Typ. 100 ms
200 ms
2 ms
Typ. 40 ms
Max. 100 ms
T
Approx. 2 s
Approx. 5 s
5)
Approx. 2 s
en