IMPORTANT PARTS

devilbiss iFill Personal Oxygen Station (Figures A & b)
1.
Oxygen Fill Connector (referred to as Fill Connector throughout guide)
2.
Oxygen Fill Connector Cover/Cylinder Adapter (referred to as Fill Connector Cover and/or Cylinder Adapter throughout guide)
3.
Oxygen Fill Port Collar (referred to as Fill Port Collar throughout guide)
4.
Instruction Label (Figure C)
5.
Indicator Panel Label (Figure C)
6.
Start/Stop Switch
7.
Cradle
8.
Fused Mains Inlet
9.
Front Handle
10. Rear Handle
11. Carry Handle Recess
12. Air Filter(s) (2 - one on each side)
13. Hour Meter - behind filter on Indicator Panel label side (right side)
iFill Instruction and Indicator Panel Labels (Figure C)
Instruction Label
1.
Set cylinder regulator to "Off"
2.
Remove cap from iFill unit
3.
Dock oxygen cylinder into oxygen fill connector, click in place
4.
Push Start/Stop button
5.
Depress port collar, lift cylinder. Replace cap
Indicator Panel Label
6.
Service Required (Red) LED
7.
Standby (Green) LED
8.
Full (Green) LED
9.
Filling (Green) LED
iFill Oxygen Cylinder (Figure d)
1.
Oxygen Fill Connector
2.
Hydrostatic Test Date - Contact your homecare provider or the cylinder manufacturer for details.
3.
Cylinder Post Valve

Accessory/Replacement Parts

1.
Air Filter(s)
535D-605 (6 filters)
2.
iFill Oxygen Cylinder w/870 Post Valve (US)
535D-M4-870
535D-M6-870
535D-C-870
535D-D-870
3.
iFill Oxygen Cylinder w/Integrated PulseDose Regulator (US)
PD1000A-M4
PD1000A-M6
PD1000A-C
PD1000A-D
iFill Oxygen Cylinder w/Integrated PulseDose Regulator (CAN)
PD1000A-CAN-M4
PD1000A-CAN-M6
PD1000A-CAN-C
PD1000A-CAN-D
4.
iFill Oxygen Cylinder w/Continuous Flow Regulator (US)
535D-M6-CF
535D-ML6-CF
535D-D-CF
535D-E-CF
iFill Oxygen Cylinder w/Continuous Flow Regulator (CAN)
535C-M6-CF
535C-ML6-CF
535C-D-CF
535C-E-CF

SET-uP

NOTE– Before operating the DeVilbiss iFill Personal Oxygen Station for the first time, locate the device where desired.

Choosing A Location

WARNING
The personal oxygen station should be at least six (6) inches away from walls, draperies, or furniture to ensure sufficient airflow.
Avoid placing the oxygen station next to heaters, radiators, or hot air registers. It should be kept at least 5 feet (1.6m) away from hot, sparking objects or naked
sources of flame.
Do not use in a closet.
Do not use in an area where the air may be contaminated with carbon monoxide as this may shorten the life of the unit (i.e. near running gasoline engines,
furnace, or heater).
EN - 4
535D-ML6-870
535D-E-870
PD1000A-ML6
PD1000A-E
PD1000A-CAN-ML6
PD1000A-CAN-E
535D-C-CF
535C-C-CF
1
7
10
8
11
Figure A
1
2
3
4
5
1
7
3
9
4
12
13
Figure B
6
7
8
9
Figure C
3
2
Figure D
535­870 series
iFill Cylinder
2
5
6
A-535-870