3M™ Inhalation Port Gasket Replacement 6895
The 6895 gasket is designed to seal the interface between the bayonet attachment inhalation ports on the facepiece and
the 6880 bayonet caps. The gaskets must be replaced whenever damaged or seal integrity is questionable.
1. Remove gaskets from facepiece inhalation port bayonet fittings.
2. Install new gaskets onto facepiece inhalation port bayonet fittings. Be certain gaskets are in proper position under all
three lugs of each bayonet port (Fig. 4).
3M™ Head Harness Replacement 6897
Read and follow Head Harness Assembly 6897 Replacement Instructions included with replacement Head Harness.
3M™ Lens Assembly 6898
The lens assembly 6898 consists of a hard coated polycarbonate lens with installed bayonet attachment inhalation port
fittings, inhalation valves, and inhalation port filter/cartridge gaskets. The 6898 lens is replaceable by following these
steps:
1. Remove center adapter assembly by turning counter-clockwise 1/4 turn and withdrawing from lens center port.
2. Remove the (2) Phillips screws from the lens/faceseal frame. Pull the frame top and frame bottom away from
faceseal.
3. Remove faceseal from lens.
4. Place new lens and faceseal together aligning marks at top and bottom. Position top and bottom frame, again
aligning marks top and bottom. Install and securely tighten screws. Make certain alignment marks are properly
aligned top and bottom with all components.
5. Install center adapter assembly.
3M™ Frame Kit 6899
The frame kit 6899 includes a frame top, frame bottom, (2) Phillips head screws and (2) hex head nuts. The frame kit
secures and seals the 3M™ 6000 series full facepiece faceseal to the 3M™ 6898 lens assembly.
1. After assembling the faceseal onto the lens, matching top and bottom alignment marks, position top frame, over lens
and faceseal, aligning center vertical marks, then press in place.
2. Position bottom frame, aligning center vertical mark, and press in place (Fig. 6).
3. Insert and tighten Phillips head screws. Make certain parts are properly aligned and sealed together.
Fig. 3
Fig. 4
9
SPECIFICATIONS
Technical
Air Flow
Weight
• Full face piece
• Motor blower
• Battery Pack (BP-17IS)
• HE filter
HE filter shelf life
Battery Pack
• Run Time
• Charging Temperature
Materials
• Respirator Visor
• Facepiece
Eye and Face Protection
Intrinsic Safety
Fig. 6
Greater than 6 CFM (170 lpm)
Approximately:
0.9 lbs. (408 g)
0.5 lbs. (227 g)
1.6 lbs. (726 g)
0.3 lbs. (136 g)
5 years
Approximately 8 hours – new battery pack and clean filter
50° and 80°F (10° and 27°C)
Polycarbonate
Silicone
Full Face 6000 series meets ANSI Z87.1-2010, high
impact level for eye and face protection
Classified for intrinsic safety ("Exia") by UL for Division I
locations: Class I, Group D; Class II, Groups E,F,G; Class III.
Temperature code "T3"
10