Installation
Speci cation
14. Specification

14.1 Dimensioned drawing

140
47
b01
30
100
c06
c01
b01
Entry electrical cables
b02 Entry electrical cables 1
c01
Cold water inlet
c06
DHW outlet

14.2 Wiring diagram

3/PE ~ 380 - 415 V
1 Heater
2 High limit safety cut-out
3 Safety pressure limiter
www.stiebel-eltron.com
105
35
114
Male thread
G 1/2 A
Male thread
G 1/2 A

14.3 Mixed water volume / outlet volume

Available temperature approx. 38 °C in the shower, for hand
washing, filling the bath etc.
Mixed water volume
Appliance
kW
Cold water inlet
6 °C
l/min
temperature
10 °C
l/min
14 °C
l/min
Outlet temperature approx. 60 °C for the kitchen sink and
when using thermostatic valves.
Outlet volume
Appliance
kW
Cold water inlet
6 °C
l/min
temperature
10 °C
l/min
14 °C
l/min
The values in the table are relative to a rated voltage of 400 V. The
outlet volume is subject to the available supply pressure and the
available mains voltage.

14.4 Application areas

Specific electrical resistance and specific electrical conductivity
Cold water inlet temperature ≤ 25 °C
Standard speci-
fication
at 15 °C
Resistance
Ω cm
≥ 900
Conductivity
mS/m ≤ 111
Conductivity
μs/cm ≤ 1110 ≤ 1000 ≤ 1250 ≤ 1120 ≤ 1360 ≤ 1230
Preheated water ' 25 °C
Standard speci-
fication
at 15 °C
Resistance
Ω cm
≥ 1200 ≥ 1300 ≥ 1070 ≥ 1175 ≥ 985
Conductivity
mS/m ≤ 83
Conductivity
μs/cm ≤ 830

14.5 Pressure drop

14.5.1 Taps/valves
Pressure drop at flow rate 10 l/min
Mono-lever mixer tap, approx.
Thermostatic valve, approx.
Hand shower, approx.
14.5.2 Sizing the pipework
When calculating the size of the pipework, a pressure drop for the
appliance of 0.1 MPa is recommended.

14.6 Fault conditions

In case of faults, loads up to a maximum of 95 °C at a pressure of
1.2 MPa can occur temporarily in the installation.
11
18
21
24
5.0
8.0
9.4
10.7
5.7
9.2
10.7
12.3
6.6
10.7
12.5
14.5
11
18
21
24
2.9
4.8
5.6
6.4
3.2
5.2
6.0
6.9
3.4
5.6
6.5
7.5
at 20 °C
at 25 °C
≥ 1000 ≥ 800
≥ 890
≥ 735
≤ 100
≤ 125
≤ 112
≤ 136
at 20 °C
at 25 °C
≤ 77
≤ 94
≤ 85
≤ 101
≤ 770
≤ 940
≤ 850
≤ 1010 ≤ 930
MPa
0.04 - 0.08
MPa
0.03 - 0.05
MPa
0.03 - 0.15
DHB-E SLi | A electronic |
27
12.1
13.8
16.1
27
7.2
7.7
8.4
≥ 815
≤ 123
≥ 1072
≤ 93
31