Vibration information
Triaxial vibration values
Uncertainty (K)
5
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1
Removing the protective sleeve
▶ Insert the tip of a screwdriver between the protective sleeve and the power tool.
5.2
Fitting the depth gauge
WARNING
Electrical hazards There is a risk of electric shock if a screw is driven into a concealed electric cable and,
at the same time, the bit holder or depth gauge is touched.
▶ Hold the screwdriver only by the grip when driving or removing screws.
When driving screws with a sealing washer, use a depth gauge suitable for the diameter of the sealing
washer (accessory). When the depth gauge is correctly adjusted the screw seal will be correctly
compressed.
The depth gauge is attached to the metal-construction screwdriver by a snap connection and can be
simply pulled off or pushed on.
▶ Fit the depth gauge.
5.3
Removing the depth gauge
CAUTION
Risk of injury The depth gauge may hinder the operator if fitted but not used.
▶ Remove the depth gauge from the tool.
▶ Pull the depth gauge forward, away from the power tool.
5.4
Setting the torque
▶ Turn the adjusting ring to the desired torque setting.
5.5
Setting forward or reverse rotation
Set the forward/reverse switch to the desired direction of rotation.
To the right for "forward" (clockwise rotation).
To the left for "reverse" (counter-clockwise rotation).
▶ Set the forward/reverse switch to the desired direction of rotation.
6
Types of work
ATTENTION
Risk of damage by incorrect handling!
▶ Do not operate the switches for direction of rotation and/or function selection during operation.
14
English
Printed: 24.07.2018 | Doc-Nr: PUB / 5070743 / 000 / 04
2
3
4
5
ST 2500
2.5 m/s²
1.5 m/s²
378505
*378505*