Gas requirements and hookup

9 CAUTION
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/
2 psig (3.5kPa.).
9 WARNING
DO NOT use a flame of any kind to check for gas
leaks.
9 CAUTION
When connecting unit to propane gas, make certain
the propane gas tank is equipped with its own high
pressure regulator in addition to the pressure
regulator supplied with the appliance. The pressure of
the gas supplied to the appliance regulator must not
exceed 14" water column (34.9 mb).
Verify the type of gas being used at the installation site.
Make certain the range matches the type of gas available
at this location.
The gas supply connections shall be made by a competent
technician and in accordance with local codes or
ordinances. In the absence of local codes, the installation
must conform to the National Fuel Gas Code ANSI
Z223.1/NFPA54- current issue.

High altitude

This appliance has been tested for operation up to an
altitude of 10,100 ft (3,078 m) elevation above sea level.
If desired, for altitudes above 2,000 feet (610 m) elevation
above sea level, adjustments can be made with a High
Altitude Kit. If flame performance is satisfactory,
adjustment will not be required. It is required that a
Certified Professional make the high altitude adjustments
during installation.
Gas requirements
Natural gas requirements:
Inlet Connection: 1/2'' NPT internal (Minimum 3/4''
dia. flex line)
Supply Pressure: 7'' min. to 14'' max. water column
(17.4 to 34.9 mb)
Manifold Pressure: 5'' water column (12.5 mb)
Page. 15
Propane gas requirements:
Inlet Connection: 1/2'' NPT internal (Minimum 3/4''
dia. flex line)
Supply Pressure: 11'' min. to 14'' max. water column
(27.4 mb to 34.9 mb)
Manifold Pressure: 10'' water column (24.9 mb)

Gas connection

To connect the gas
1. Make sure the gas supply is turned off at the manual
shut-off valve before connecting the appliance.
2. Use a ¾'' (19 mm) flex line to connect between the
gas supply and the appliance gas inlet. The gas supply
line connection is located at the lower right portion.
The appliance gas inlet connection is ½'' (12.7 mm)
NPT.
Use caution to avoid crimping the ¾'' (19 mm) flex
line when making bends. Suggested length of flex
line is 48" (1219 mm); however, please check local
codes for your area's requirements before
installation.
¾" (19) external threads
¾" (19) external threads
¾" (19) external threads
½" (12.7) internal threads
½" (12.7) internal threads
½" (12.7) internal threads
3. Use pipe sealing compound or Teflon
pipe threads. DO NOT apply sealing compound or
tape to flare fittings. Take care not to apply excessive
pressure when tightening the fittings.
4. Leak testing of the appliance shall be in accordance
with the following instructions:
Turn on gas and check supply line connections for
leaks using a soap and water solution.
Bubbles forming indicate a gas leak. Repair all
leaks immediately.
{
¾" (19)
¾" (19)
¾" (19)
Flex line
Flex line
Flex line
inches (mm)
®
tape on the