5.5.11 – Delete all memorised transmitters
command
Deletes all the transmitters from the motor.
Structure
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
CMD
IND
04
The data field is empty.
Example
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
CMD
01
04
Response
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
RISP
01
04
5.5.12 – Delete motor parameters command
Deletes all the limit switch data from the motor.
Structure
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
CMD
IND
04
The data field is empty.
Command
Data
CR
[AA]
65
–
–
Command
Data
CR
[AA]
65
–
–
Command
Data
CR
[AA]
65
–
–
Command
Data
CR
[AA]
66
–
–
Example
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
CMD
01
04
Response
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
RISP
01
04
5.6 – Commands for memorising and viewing
lists
Two commands lists (max. 30 commands) can be stored.
The commands are then executed sequentially in the event
of a transition of the 12 V input trigger, or when the up or
down trigger event is set from the transmitter.
The serial port command to store commands that will be
executed when the signal moves from low to high is::
MEM_ON [XX] [YY] [XX1] [YY1] [...] [...] [Carriage Return]
Note – The fields are one space apart and the string ends
with Carriage Return.
Important! - Address 1 is used for sending commands
to the mechanical motor.
The fields are:
MEM_ON It is the string that stores the commands in the
first list.
Command
Data
CR
[AA]
66
–
–
Command
Data
CR
[AA]
66
–
–