Temperature range
Nominal (rated) temperature
Storage temperature
Enclosure dimensions
Enclosure materials
Housing
Screws
Screwed cable glands
EMC/Ex bolted connections
Vent plugs
Weight, approx.
Degree of protection per EN 60529
Current consumption ≤ 100 mA +Excitation voltage UB = 5 V / Bridge resistance RB
1)
AED9101D-Z2/22
General information on explosion protection
2.5
General additional hints
S Choose a connecting cable of a quality that complies
with the relevant mechanical and thermal require
ments.
S The test voltage of the cables has to withstand
AC 500 V minimum.
2.5.1
Special pre-cautions
S Screen is connected to the housing, Equipotential
bonding has to be provided between the earth con
nection of control device and the enclosure of the
AED.
A4624-1.0 HBM: public
°C
°C
mm
190 x 65 x 40
Cast aluminum alloy,
AISi ENAC‐4430
DIN EN 1706, unpainted
3 x M16x1.5
50.616M/EMC/EX
1 x M16x1.5 10.615M/G/EX
g
-20 .. 60
-40 .. 85
rustfree
500
IP65
11