DANGER
provide a fresh air opening in the
heated space of at least three square feet
(2,800 sq. cm) for each 100,000 BTU / Hr.
of heater output. Provide a larger opening if
more heaters are being used.
Always disconnect the heater from the LP
cylinder before putting the heater into storage. If
for any reason the heater is to be stored indoors,
the tank MUST be disconnected from the LP
cylinder, and the cylinder stored outdoors in a
well-ventilated area, out of the reach of children,
and in accordance with the Standard for Storage
and Handling of Petroleum Gases, ANSI/NFPA
58 - latest edition and Natural Gas and Propane
Installation Code, CSA B149.1. The plastic valve
plug or valve cover supplied with the cylinder
must be re-installed on the valve to protect the
fitting from damage.
© 2015, Pinnacle Products International, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
Ventilation
procedures. This should include cleaning the
inside of the heater once a month and checking
the spark gap at least once a heating season.
Re-gap the terminals to 0.160" (4mm)
8
40-GFA 60V-GFA-A 125V-GFA-A 150V-GFA-A
1.2 ft.
2
1.8 ft.
2
1110 cm
2
1670 cm
DANGER
DANGER
be sure to follow proper maintenance
Propane Forced Air Heater User's Manual
3.8 ft.
2
4.5 ft.
2
3530 cm
2
4180 cm
2