Carbon-zinc type
Alkaline type
Lithium type
The SAFETY LIGHT portion is powered by one (1) 9V alkaline bat-
tery. Under normal (standby) conditions, the battery should last at
least one year and provide 15 minutes of pulsating light when the
alarm is sounding.
NOTE: WEEKLY TESTING IS REQUIRED! IF THE SAFETY LIGHT
APPEARS DIM DURING REGULAR TESTING, REPLACE BOTH
BATTERIES IMMEDIATELY.
USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR FOR
SAFETY LIGHT BATTERY REPLACEMENT.
ENERGIZER 522; DURACELL MN1604,MX1604; GOLD PEAK
1604A
PANASONIC 6AM6, 6AM-6, 6AM-6PI, 6AM6X, AND 6LR61(GA)
WARNING!! BE SURE TO FOLLOW BATTERY INSTALLATION
INSTRUCTIONS PRINTED ON THE INSIDE OF THE BATTERY
DOOR AND USE ONLY THE BATTERIES SPECIFIED. USE OF
DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT
ON THE SMOKE ALARM.
LAMP REPLACEMENT: The Safety Light uses a 6.3 volt 250mA
fuse type lamp which has an average life of 50 hours. If the
Safety Light does not operate with a fresh alkaline battery, replace
the lamp. To replace the lamp, remove the alarm from trim ring
by following the ALARM REMOVAL instructions at the beginning
of this section. Open the battery door and remove both batteries
from the unit. Grip the lamp holder with your thumb and finger
(see Figure 10) and pull out the lamp holder assembly (see Figure
10A). Slide the old lamp out of the lamp holder and replace it
with a new lamp (see Figure 10B).
FIGURE 10
EVEREADY 216 OR 1222; GOLD PEAK 1604P
OR 1604S
ENERGIZER 522; DURACELL MN1604,
MX1604; GOLD PEAK 1604A; PANASONIC
6AM6, 6AM-6, 6AM-6PI, 6AM6X, AND 6LR61 (GA)
ULTRALIFE U9VL-J
FIGURE 10A
FIGURE 10B