Settings for the "Timer" function (SET-menu)
Vxx (Decelerator):
One event
Several actions
Events to be enabled
TIME
TIME
TIME
Sequence of program lines
26
Cycle tells you often the action should be repeated.
Switching time tells you when the action should take place.
The example (here shown as program line 04) means:
Each day at 15:23 the clock causes the pump to switch to the "Contact" operating mode at a factor of 50.
Cycle
Illustrated in display
HOUR
–
DAILY
D
WORK
W
W'END
E
WEEK
–
2WEEK
1/2
Tab. 3: Cycles
* In this case the timer is not related to the calendar weeks
IMPORTANT
• In the case of two week cycles the timer does not relate to calendar weeks.
In the "second week" a dot appears after the weekday in the permanent display
(see "Permanent displays" at the start of the instructions). It is therefore possible that the
permanent display in the first calendar week displays the "Second week".
• Using the TIME event enabling you can trigger an action to the minute. To trigger an action
to the second you need to use a decelerator.
A decelerator Vxx can be used to delay an action with regard to an event to be enabled.
Example:
06
AUX
07
V 3
The example means:
When the contact for the auxiliary frequency is closed, the decelerator V 3 starts and will cause relay 1 to
switch after 125 s.
A program line with a "Decelerator" Vxx event to be enabled therefore still has the component "Delay time".
Vxx itself must previously be called up as action Vxx before an event to be enabled. A decelerator can also
be the action of another decelerator. You can employ 13 decelerators at a time (V 0, V 1, . . . , V12).
Event to be enabled
Vxx
The example means:
The decelerator causes relay 1 to switch to ON after 125 s.
The delay time tells you the time by which the selected action has been delayed
(0 s. . . 32767 s = 9 h 6 min 7 s).
IMPORTANT
You can time an action to the second with Vxx event enabling. The clock in the gamma/ L is
accurate to ± 2 s/24 h.
You can allocate several actions to one event. Always select the same cycle and the same switching time:
Cycle
Switching time
DAILY
12:45
DAILY
12:45
DAILY
12:45
After programming has been completed the timer software automatically incorporates all newly programmed
program lines into the correct positions
Just timed timer programs also proceed in this sequence.
A timer program can have a maximum of 82 program lines (00 ... 81).
V 3
00125
Rel 1
Delay time
Action
00125
Rel 1
Action
CNTCT
Rel 2
V12
in the timer program (see section 2. 2).
Description
Every hour
Every day
Every weekday (Mo – Fr)
Every weekend day (Sa, So)
Every week
Every 14 days*.
ON
Specification
ON
Specification
00050
OFF
--