Mounting the FH8000F (Furnace) Honeywell Enhanced Air
Cleaner
NOTE: For mounting a FH8000A model go back to page 7.
CAUTION: Personal Injury Hazard.
Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs.
Use care and wear appropriate protective clothing and gloves when handling parts.
STEP ONE: Identify the Mounting Location and Orientation
a. Identify a mounting orientation for the Honeywell Enhanced Air Cleaner in the return air duct. See Fig. 7 and
Fig. 8 on page 11.
b. Ensure airflow direction through the Honeywell Enhanced Air Cleaner matches the arrows on the face of the
air filter cartridge. The Honeywell Enhanced Air Cleaner door can be rotated 180 degrees to accommodate the
cabinet orientation.
c. The location of the unit should be readily accessible. Enough clearance room should be provided to remove
the door and filter for replacement.
AIRFLOW
UPFLOW FURNACE WITH SIDE RETURN
10
NOTE:
MOUNTING ON THIS SIDE
REQUIRES THE CABINET
TO BE ROTATED 180° FOR
CORRECT AIRFLOW.
HORIZONTAL APPPLICATION
Fig. 7. Cabinet Orientation for FH8000F models.
UPFLOW FURNACE WITH BOTTOM MOUNT
TrueCLEAN™ Enhanced Air Cleaner 68-0308EFS—03
AIRFLOW
DOWNFLOW FURNACE WITH BOTTOM MOUNT
AIRFLOW
M28905