Mounting the FH8000A (Air Handler) Honeywell Enhanced Air
Cleaner
NOTE: For mounting a FH8000F model go to page 10.
CAUTION: Personal Injury Hazard.
Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs.
Use care and wear appropriate protective clothing, eye protections, and gloves when handling parts.
STEP ONE: Identify the Mounting Location and Orientation
a. Identify a mounting orientation for the Honeywell Enhanced Air Cleaner in the return air duct (see Fig. 4).
b. Ensure airflow direction through the Honeywell Enhanced Air Cleaner matches the arrows on the face of the
filter. The Honeywell Enhanced Air Cleaner or door can be rotated 180 degrees to accommodate the cabinet
orientation.
c. The location of the unit should be readily accessible. Enough room should be provided to remove the door and
filter for periodic replacement of the air filters.
Airflow
Downflow
TrueCLEAN™ Enhanced Air Cleaner 68-0308EFS—03
Horizontal
Fig. 4. Cabinet Orientation for FH8000A models.
Airflow
Upflow
M28902
7