ERROR CODE
ER03 - the hob turns off after
10 seconds and beeps
permanently
ER40
ER47
U400
ER21 - E/2
ER20,ER22,ER31,ER36
E/4, E/5, E/6,E/8,E/9
E/A
Customer service
Before contacting Customer Service
1.Check that you cannot solve the problem yourself based on
the points described in "Troubleshooting".
2.Switch the device off and on again to see if the problem
resolves itself.
If, after the above checks, the fault persists, contact the
nearest Customer Service.
Troubleshooting
DESCRIPTION
Permanent pressure on the
command zone
The network voltage is causing
overheating
Communication with the electric
network is faulty (the control panel
switches off - the cooking zones no
longer respond)
The hob connection is not of the
correct voltage (wrong
connection/overvoltage)
The command zone switches off due
to too high a temperature
Call customer service and report the error code
POSSIBLE CAUSES
Water or kitchen utensils
on the command zone
The secondary voltage of
the network is too low
The power cable was
incorrectly connected or
is faulty
A different voltage is
detected from that of the
connection
The temperature inside
the electronic parts is too
high
27
ERROR REMOVAL
Clean the command
zone
Disconnect the hob from
the mains and check the
connection
Disconnect the hob from
the mains and check the
connection
Disconnect the hob from
the mains and check the
connection
Wait for the hob to cool
before reusing it