Integral Keypad - Hmi - WEG CVW300 Guia De Instalacion

Convertidor de frecuencia para tracción eléctrica
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Variable Speed Drive for Electric Traction
NOTE!
In case the contactor does not have an auxiliary
contact, it is necessary to short the pins 17 and 18
of XC10; otherwise, the inverter will show fault F185.
INTEGRAL KEYPAD – HMI
The HMI for the CVW300 is supplied as an accessory and must be
purchased separately. For detailed information please refer to the
CVW300 user's manual.
1. Press this key to go
back to the previous
- USB communication
group.
port
2. Press this key to go to
the next parameter.
3. Press this key
to increase the
parameter value.
1. Press this key to
go back to the
monitoring mode.
2. Press this key to
go back to the
previous level in the
parameterization
mode.
3. Press this key to
cancel the new value
and go back to the
previous level.
- Press this key to
define the motor
rotation.
This option is active
when:
P0223 = 2 or 3 in
LOC and/or
P0226 = 2 or 3 in
REM.
- Press this key to
toggle between
LOCAL and REMOTE
mode.
This option is active
when:
P0220 = 2 or 3.
- Press this key to accelerate the motor up to the speed set in P0122. The motor
speed is maintained while the key is pressed. When the key is released the
motor decelerates up to its complete stop.
This function is active when all the following conditions are met:
1. Start/Stop = Stop.
2. General Enable = Active.
3. P0225 = 1 in LOC and/or P0228 = 1 in REM.
Figure 8: Operator keys
NOTE!
It is necessary to set the password at P0000 for
parameter modification; otherwise the parameters
contents can only beviewed.
The default password for P0000 is 5. It is possible to
change the password at P0200. Refer to the CVW300
user's manual.
10 | CVW300
Menu
(parameters
group
selection)
– only one
parameter
group is
shown
ateach time.
1. Press this key to
decrease the speed.
2. Press this key to go to
the next group.
3. Press this key to go
back to the previous
parameter.
4. Press this key
to decrease the
Parameter groups available at the Menu:
parameter value.
ƒ
PARAM: all parameters.
ƒ
READ: only the reading parameters.
1. Press this key to enter
ƒ
in the programming
MODIF: only the parameters changed compared to the factory
mode.
default.
2. Press this key to select
ƒ
BASIC: basic application parameters.
the desired parameter
group.
ƒ
MOTOR: parameters related to motor data control.
3. Press this key to show
ƒ
I/O: parameters related to the digital and analog inputs/outputs.
the parameter.
ƒ
4. Press this key to save
NET: parameters related to the communication protocol.
the parameter value.
ƒ
HMI: parameters for the keypad configuration.
ƒ
SPLC: parameters related to the SoftPLC function.
- Press this key to
accelerate the motor
ƒ
STARTUP: parameters for the oriented startup.
according to the
acceleration ramp time.
Inverter status:
This option is active
when:
ƒ
LOC: command source or local reference.
P0224 = 0 in LOC and/or
ƒ
REM: command source or remote reference.
P0227 = 0 in REM.
ƒ
: motor rotation according to the arrows.
- Press this key to
ƒ
CONF: configuration. It indicates that the inverter is in the Oriented
decelerate the motor
Start-up routine or with in compatible parameter programming.
according to the
deceleration ramp time.
Refer section 5.6 Incompatibility Between Parameters in the user's
This option is active
manual of the CVW300.
when:
ƒ
SUB: Battery undervoltage.
P0224 = 0 in LOC and/or
ƒ
P0227 = 0 in REM.
RUN: inverter enabled and/or DC braking activated.
Return
Advance
Local/Remote
Motor
(commands and
Inverter
rotation
references source)
status
Main display
Figure 9: Display sections
Secondary
display
Variable
unit (shows
the value
of the main
display)
Variable
monitoring
bar graph
Index
Tabla de contenido
loading

Tabla de contenido